MAINTENANCE AND TROUBLESHOOTING MAINTENANCE Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. See the drawing below. Remove the M8 x 14mm Shoulder Screw (89), the Roller Arm Cover (58), and the M8 Washer (not shown) from the Left Roller Arm (40). To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. HOW TO GREASE THE TRACKS For optimal performance, apply a small amount of PTFE grease to the tracks on the ramp every three months. See assembly step 13 on page 11 for instructions. CONSOLE TROUBLESHOOTING 28 29 89 58 40 38 If lines appear in the console display, see HOW TO CHANGE CONSOLE SETTINGS on page 22 and adjust the contrast level of the display. If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 16. See assembly step 10 on page 10. Remove the Upper Body Covers A and B (31, 32) from the Left Upper Body Arm (27). See assembly step 9 on page 10. Remove the Left Upper Body Arm (27) from the Left Upper Body Leg (28). If a replacement power adapter is needed, call the telephone number on the cover of this manual. IMPORTANT: To avoid damaging the console, use only a manufacturer-supplied regulated power adapter. See the drawing above. Remove the Left Roller Arm (40), the Left Pedal Arm (38), and the Left Upper Body Leg (28) from the elliptical. Then, using a flat screwdriver, gently pry off the left Disc (29). HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. First, unplug the power adapter. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

23
MAINTENANCE
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
HOW TO GREASE THE TRACKS
For optimal performance, apply a small amount of
PTFE grease to the tracks on the ramp every three
months. See assembly step 13 on page 11 for
instructions.
CONSOLE TROUBLESHOOTING
If lines appear in the console display, see HOW TO
CHANGE CONSOLE SETTINGS on page 22 and
adjust the contrast level of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 16.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
First, unplug the
power adapter.
See the drawing below.
Remove the M8 x 14mm
Shoulder Screw (89), the Roller Arm Cover (58),
and the M8 Washer (not shown) from the Left Roller
Arm (40).
See assembly step 10 on page 10.
Remove the
Upper Body Covers A and B (31, 32) from the Left
Upper Body Arm (27).
See assembly step 9 on page 10.
Remove the
Left Upper Body Arm (27) from the Left Upper Body
Leg (28).
See the drawing above.
Remove the Left Roller Arm
(40), the Left Pedal Arm (38), and the Left Upper Body
Leg (28) from the elliptical. Then, using a flat screw-
driver, gently pry off the left Disc (29).
89
58
40
29
28
38