HP 1032 HP High Performance Clusters LC 3000 Series Cabling Guide - Page 71

Table 13-2, Node Fast Ethernet Cabling for DL145 LC Clusters Expandable to 192 Nodes

Page 71 highlights

64 Node Fast Ethernet Expandable to 192 Nodes Table 13-2: 64 Node Fast Ethernet Cabling for DL145 LC Clusters Expandable to 192 Nodes continued OOB Switch Cabling Cluster Interconnect Switch Cabling IB Management Switch Cabling Origin (server) Destination (switch) Origin (server) Destination (switch) Origin (server) Destination (switch) R1-S14-IPMI R1-SW2-P14 R1-S14-NIC1 R2-SW1-MC-P22 R1-S14-NIC2 R1-SW1-P14 R1-S15-IPMI R1-SW2-P15 R1-S15-NIC1 R2-SW1-MC-P23 R1-S15-NIC2 R1-SW1-P15 R1-S16-IPMI R1-SW2-P16 R1-S16-NIC1 R2-SW1-MC-P24 R1-S16-NIC2 R1-SW1-P16 R1-S17-IPMI R1-SW2-P17 R1-S17-NIC1 R2-SW1-MD-P1 R1-S17-NIC2 R1-SW1-P17 R1-S18-IPMI R1-SW2-P18 R1-S18-NIC1 R2-SW1-MD-P2 R1-S18-NIC2 R1-SW1-P18 R1-S19-IPMI R1-SW2-P19 R1-S19-NIC1 R2-SW1-MD-P3 R1-S19-NIC2 R1-SW1-P19 R1-S20-IPMI R1-SW2-P20 R1-S20-NIC1 R2-SW1-MD-P4 R1-S20-NIC2 R1-SW1-P20 R1-S21-IPMI R1-SW2-P21 R1-S21-NIC1 R2-SW1-MD-P5 R1-S21-NIC2 R1-SW1-P21 R1-S22-IPMI R1-SW2-P22 R1-S22-NIC1 R2-SW1-MD-P6 R1-S22-NIC2 R1-SW1-P22 R1-S23-IPMI R1-SW2-P23 R1-S23-NIC1 R2-SW1-MD-P7 R1-S23-NIC2 R1-SW1-P23 R1-S24-IPMI R1-SW2-P24 R1-S24-NIC1 R2-SW1-MD-P8 R1-S24-NIC2 R1-SW1-P24 R1-S25-IPMI R1-SW2-P25 R1-S25-NIC1 R2-SW1-MD-P9 R1-S25-NIC2 R1-SW1-P25 R1-S26-IPMI R1-SW2-P26 R1-S26-NIC1 R2-SW1-MD-P10 R1-S26-NIC2 R1-SW1-P26 R1-S27-IPMI R1-SW2-P27 R1-S27-NIC1 R2-SW1-MD-P11 R1-S27-NIC2 R1-SW1-P27 R1-S28-IPMI R1-SW2-P28 R1-S28-NIC1 R2-SW1-MD-P12 R1-S28-NIC2 R1-SW1-P28 R1-S29-IPMI R1-SW2-P29 R1-S29-NIC1 R2-SW1-MD-P13 R1-S29-NIC2 R1-SW1-P29 R1-S30-IPMI R1-SW2-P30 R1-S30-NIC1 R2-SW1-MD-P14 R1-S30-NIC2 R1-SW1-P30 R1-S31-IPMI R1-SW2-P31 R1-S31-NIC1 R2-SW1-MD-P15 R1-S31-NIC2 R1-SW1-P31 R1-S32-IPMI R1-SW2-P32 R1-S32-NIC1 R2-SW1-MD-P16 R1-S32-NIC2 R1-SW1-P32 R1-S33-IPMI R1-SW2-P33 R1-S33-NIC1 R2-SW1-MD-P17 R1-S33-NIC2 R1-SW1-P33 R1-S34-IPMI R1-SW2-P34 R1-S34-NIC1 R2-SW1-MD-P18 R1-S34-NIC2 R1-SW1-P34 R1-S35-IPMI R1-SW2-P35 R1-S35-NIC1 R2-SW1-MD-P19 R1-S35-NIC2 R1-SW1-P35 R1-S36-IPMI R1-SW2-P36 R1-S36-NIC1 R2-SW1-MD-P20 R1-S36-NIC2 R1-SW1-P36 R1-S37-IPMI R1-SW2-P37 R1-S37-NIC1 R2-SW1-MD-P21 R1-S37-NIC2 R1-SW1-P37 R1-S38-IPMI R1-SW2-P38 R1-S38-NIC1 R2-SW1-MD-P22 R1-S38-NIC2 R1-SW1-P38 R1-S39-IPMI R1-SW2-P39 R1-S39-NIC1 R2-SW1-MD-P23 R1-S39-NIC2 R1-SW1-P39 R1-S40-IPMI R1-SW2-P40 R1-S40-NIC1 R2-SW1-MD-P24 R1-S40-NIC2 R1-SW1-P40 R2-S1-IPMI R2-SW3-P1 R2-S1-NIC1 R2-SW1-MB-P1 R2-S1-NIC2 R2-SW2-P1 R2-S2-IPMI R2-SW3-P2 R2-S2-NIC1 R2-SW1-MB-P2 R2-S2-NIC2 R2-SW2-P2 R2-S3-IPMI R2-SW3-P3 R2-S3-NIC1 R2-SW1-MB-P3 R2-S3-NIC2 R2-SW2-P3 continued 13-4 HP High Performance Clusters LC 3000 Series Cabling Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

64 Node Fast Ethernet Expandable to 192 Nodes
Table 13-2:
64 Node Fast Ethernet Cabling for DL145 LC Clusters Expandable to 192 Nodes
continued
OOB Switch Cabling
Cluster Interconnect Switch Cabling
IB Management Switch Cabling
Origin (server)
Destination
(switch)
Origin (server)
Destination
(switch)
Origin (server)
Destination
(switch)
R1-S14-IPMI
R1-SW2-P14
R1-S14-NIC1
R2-SW1-MC-P22
R1-S14-NIC2
R1-SW1-P14
R1-S15-IPMI
R1-SW2-P15
R1-S15-NIC1
R2-SW1-MC-P23
R1-S15-NIC2
R1-SW1-P15
R1-S16-IPMI
R1-SW2-P16
R1-S16-NIC1
R2-SW1-MC-P24
R1-S16-NIC2
R1-SW1-P16
R1-S17-IPMI
R1-SW2-P17
R1-S17-NIC1
R2-SW1-MD-P1
R1-S17-NIC2
R1-SW1-P17
R1-S18-IPMI
R1-SW2-P18
R1-S18-NIC1
R2-SW1-MD-P2
R1-S18-NIC2
R1-SW1-P18
R1-S19-IPMI
R1-SW2-P19
R1-S19-NIC1
R2-SW1-MD-P3
R1-S19-NIC2
R1-SW1-P19
R1-S20-IPMI
R1-SW2-P20
R1-S20-NIC1
R2-SW1-MD-P4
R1-S20-NIC2
R1-SW1-P20
R1-S21-IPMI
R1-SW2-P21
R1-S21-NIC1
R2-SW1-MD-P5
R1-S21-NIC2
R1-SW1-P21
R1-S22-IPMI
R1-SW2-P22
R1-S22-NIC1
R2-SW1-MD-P6
R1-S22-NIC2
R1-SW1-P22
R1-S23-IPMI
R1-SW2-P23
R1-S23-NIC1
R2-SW1-MD-P7
R1-S23-NIC2
R1-SW1-P23
R1-S24-IPMI
R1-SW2-P24
R1-S24-NIC1
R2-SW1-MD-P8
R1-S24-NIC2
R1-SW1-P24
R1-S25-IPMI
R1-SW2-P25
R1-S25-NIC1
R2-SW1-MD-P9
R1-S25-NIC2
R1-SW1-P25
R1-S26-IPMI
R1-SW2-P26
R1-S26-NIC1
R2-SW1-MD-P10
R1-S26-NIC2
R1-SW1-P26
R1-S27-IPMI
R1-SW2-P27
R1-S27-NIC1
R2-SW1-MD-P11
R1-S27-NIC2
R1-SW1-P27
R1-S28-IPMI
R1-SW2-P28
R1-S28-NIC1
R2-SW1-MD-P12
R1-S28-NIC2
R1-SW1-P28
R1-S29-IPMI
R1-SW2-P29
R1-S29-NIC1
R2-SW1-MD-P13
R1-S29-NIC2
R1-SW1-P29
R1-S30-IPMI
R1-SW2-P30
R1-S30-NIC1
R2-SW1-MD-P14
R1-S30-NIC2
R1-SW1-P30
R1-S31-IPMI
R1-SW2-P31
R1-S31-NIC1
R2-SW1-MD-P15
R1-S31-NIC2
R1-SW1-P31
R1-S32-IPMI
R1-SW2-P32
R1-S32-NIC1
R2-SW1-MD-P16
R1-S32-NIC2
R1-SW1-P32
R1-S33-IPMI
R1-SW2-P33
R1-S33-NIC1
R2-SW1-MD-P17
R1-S33-NIC2
R1-SW1-P33
R1-S34-IPMI
R1-SW2-P34
R1-S34-NIC1
R2-SW1-MD-P18
R1-S34-NIC2
R1-SW1-P34
R1-S35-IPMI
R1-SW2-P35
R1-S35-NIC1
R2-SW1-MD-P19
R1-S35-NIC2
R1-SW1-P35
R1-S36-IPMI
R1-SW2-P36
R1-S36-NIC1
R2-SW1-MD-P20
R1-S36-NIC2
R1-SW1-P36
R1-S37-IPMI
R1-SW2-P37
R1-S37-NIC1
R2-SW1-MD-P21
R1-S37-NIC2
R1-SW1-P37
R1-S38-IPMI
R1-SW2-P38
R1-S38-NIC1
R2-SW1-MD-P22
R1-S38-NIC2
R1-SW1-P38
R1-S39-IPMI
R1-SW2-P39
R1-S39-NIC1
R2-SW1-MD-P23
R1-S39-NIC2
R1-SW1-P39
R1-S40-IPMI
R1-SW2-P40
R1-S40-NIC1
R2-SW1-MD-P24
R1-S40-NIC2
R1-SW1-P40
R2-S1-IPMI
R2-SW3-P1
R2-S1-NIC1
R2-SW1-MB-P1
R2-S1-NIC2
R2-SW2-P1
R2-S2-IPMI
R2-SW3-P2
R2-S2-NIC1
R2-SW1-MB-P2
R2-S2-NIC2
R2-SW2-P2
R2-S3-IPMI
R2-SW3-P3
R2-S3-NIC1
R2-SW1-MB-P3
R2-S3-NIC2
R2-SW2-P3
continued
13-4
HP High Performance Clusters LC 3000 Series Cabling Guide