HP 225338-B21 Configuring Arrays on HP Smart Array Controllers Reference Guide - Page 87
ACU scripting error messages, Warning, Warning message, Comment or clarification, Error, Error message
UPC - 720591650551
View all HP 225338-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
Warning code 4002 Warning message Chassis name is already set to this value 4003 4004 One or more controller commands were skipped because the controller is not configured Using Repeat function Comment or clarification The chassis name is already set to the supplied value. The command is ignored. Certain commands require that the controller be configured before they can be sent to the controller. Some commands have been ignored because the Repeat parameter has been specified in the input file. ACU scripting error messages Error code 0 Error message - 2053 Too many coinciding expansion, migration, or extension operations 2056 2059 2064 2817 2818 2819 2821 2823 2824 Controller does not support license keys Invalid license key Controller does not support SSP Invalid Action Invalid Method Invalid Controller No controllers detected Invalid Rebuild Priority Invalid Expand Priority 2825 2826 Invalid Array Array not specified 2827 New Array ID does not match the next available Array ID. 2828 New Array ID already exists Comment or clarification No error exists. The program completed successfully. The new configuration requires more transformations than are possible at one time. For example, you cannot expand a logical volume and transform its RAID level at the same time. The controller does not support license key entry or deletion. The entered license key is not a valid license key. The controller does not support SSP functions. The requested actions are invalid, for example, combining -reset with capture mode. The method must be either Custom or Auto. An invalid controller value was specified. No controllers were detected. This error applies to Input mode only. The specified rebuild priority is not supported. The specified expand priority is not supported. This error also occurs if the controller does not allow expansion, and therefore, does not support expand priority. The array ID is invalid. The Array command is missing from the script file. Some commands were found that require an Array to be specified. The array ID in the script file does not match the array ID of the next available array. For example, if the configuration has an Array A and the input file specifies Array C (without Array B), then the script generates this error. The array ID specified in the script file (in Configure mode) already exists in the HP Array Configuration Utility 87