HP 32Sii HP 32Sii RPN Scientific Calculator - (English) Owner Manual - Page 226
Restrictions o Solving and Integrating
UPC - 088698055250
View all HP 32Sii manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 226 highlights
The e((D−M)÷S)2 ÷2 function is calculated by the routine labeled F. Other routines prompt for the known values and do the other calculations to find Q(D), the upper-tail area of a normal curve. The integration itself is set up and executed from routine Q: G Recalls lower limit of integration. Recalls upper limit of integration. (X = D.) Specifies the function. Integrates the normal function using the dummy variable D. Restrictions o Solving and Integrating The SOLVE variable and ∫ FN d variable instructions cannot call a routine that contains another SOLVE or ∫ FN instruction. That is, neither of these instructions can be used recursively. For example, attempting to calculate a multiple integral will result in an ∫1∫2 error. Also, SOLVE and ∫ FN cannot call a routine that contains an /label instruction; if attempted, a or error will be returned. SOLVE cannot call a routine that contains an ∫FN instruction (produces a #1∫2 error), just as ∫ FN cannot call a routine that contains a SOLVE instruction (produces an ∫1 #2 error). The SOLVE variable and ∫FN d variable instructions in a program use one of the seven pending subroutine returns in the calculator. (Refer to "Nested Subroutines" in chapter 13.) The SOLVE and ∫FN operations automatically set Decimal display format. 14-10 Solving and Integrating Programs File name 32sii-Manual-E-0424 Printed Date : 2003/4/24 Size : 17.7 x 25.2 cm