HP 4400 HP StorageWorks Fabric OS 6.3.2b Release Notes (5697-0777, November 20 - Page 42
Fixed in Fabric OS 6.3.2., Workaround prior to upgrade
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Access Control Lists are not getting populated, even though the ACL Policies are set on the switch. As a result, ACL related configuration is not possible through DCFM or other common access layer (CAL) interfaces, even though it can be done through the CLI. This issue affects only the HP StorageWorks 2408 FCoE switch and 10/24 FCoE blade. Workaround prior to upgrade: Use the CLI. Fixed in Fabric OS 6.3.2. CNA cannot login during shut/no shut of port that occurs in the middle of FCoE login attempt. Doing fcoe -enable/disable does not recover it. This issue affects only the HP StorageWorks 2408 FCoE switch and 10/24 FCoE blade. Fixed in Fabric OS 6.3.2. After a firmwaredownload hafailover/hareboot, switch is missing domain route, indicated by RTWR-1003 retry messages. Only pertinent to fabric with VE link to 1606 Extension SAN switch or Multiprotocol Extension blade in IM2 mode. Fixed in Fabric OS 6.3.2. A device with a node WWN of zero connected to an NPIV port that is queried by CALD, causes the switch to panic and reboot about every Fixed in Fabric OS 6.3.2. 20 to 30 minutes. With a switch in Access Gateway mode, a few ports were observed as persistently disabled after enabling QoS on all trunked F_Ports, with the message: Area of those ports had been acquired by the ports that were not in the same trunk. Occurs when port SCNs come in an unexpected order. Fixed in Fabric OS 6.3.2. A switch panic occurs during reboot due to a race condition caused by a data structure not yet being allocated by a daemon and yet another daemon querying it. Applies only to the 2408 FCoE switch and 10/24 FCoE blade. Fixed in Fabric OS 6.3.2. Routes are not being properly rebalanced after a trunk group loses a member, which could lead to sluggish performance on 8Gb switches if there is a slow drain device using the lower bandwidth link to further congest the fabric. Workaround prior to upgrade: Keep trunk groups with equal bandwidth. Fixed in Fabric OS 6.3.2. Detected termination of zoning daemon process during firmwaredownload. Race condition triggered the zoning daemon to access unintial- Fixed in Fabric OS 6.3.2. ized global memory and then crash. May see frame drops on some device ports and E_Ports after hafailover. E_Port change SCN event or fabric unstable event results in fspf routing protocol incorrectly mapping slave to master port or incorrectly programming interface IDs on the trunks. Frames are routed to the wrong port and dropped. Workaround prior to upgrade: May need to block and unblock all ports in the trunk to recover from the rare condition. Fixed in Fabric OS 6.3.2. FCR matrix specifies which FCR pairs can talk to each other. All edge fabrics connected to the defined pair of FCRs are allowed to import devices to each other. However, after a fabric event, FCR did not handle domain unreachable SCN timing sequence correctly, leading to the FCR matrix information being out of sync among all FCRs in the fabric; all imported disks went to configured. Workaround prior to upgrade: Disable FCR matrix by issuing the following commands: 1. fcrlsanmatrix -remove -fcr wwn wwn 2. fcrlsanmatrix -apply fcr Fixed in Fabric OS 6.3.2. 42