HP AM866A Brocade Converged Enhanced Ethernet Command Reference v6.3.0 (53-100 - Page 32
Use this command to set the interval; the command interpreter waits for user input detected. Use
UPC - 884420064602
View all HP AM866A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
2 exec-timeout exec-timeout Sets the interval that the EXEC command interpreter wait for user input. Synopsis exec-timeout minutes seconds no exec-timeout Operands minutes seconds Specifies the time interval in minutes. The range is 0-35791. Specifies the time interval in seconds. The range is 0-2147483. Defaults The default is 10 minutes. Command Console and VTY (line) configuration mode Modes Description Use this command to set the interval; the command interpreter waits for user input detected. Use no exec-timeout to disable the wait interval that the command interpreter waits. Usage The exec-timeout command is used to set the time the Telnet session waits for an idle VTY session, Guidelines before it time outs. An exec-timeout setting of 0 (zero) causes the Telnet session to wait indefinitely. Examples To configure the wait interval for the console session: switch(config)#line console 0 switch(conf-line)#exec-timeout 2 30 switch(config)#line vty 0 9 switch(conf-line)#exec-timeout 30 30 See Also show line, line vty, line console 14 Converged Enhanced Ethernet Command Reference 53-1001347-01