HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 146
HP_DeviceIndication: Enclosure Fan status, changed to Degraded
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 146 highlights
4-4-26 HP_DeviceIndication: Enclosure Fan status changed to Degraded Table 4-111 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name IndicationIdentifier PerceivedSeverity IndicationTime Description AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions SystemName SystemCreationClassName Summary EventCategory ProbableCause ProbableCauseDescription NetworkAddresses OSType Property implementation CIM_Indication GUID string generated at indication 3 (Warning) Time of indication CIM_AlertIndication A Storage Enclosure Fan status changed to a status of Degraded. An enclosure has detected there may a problem with one or more of the fans. WBEM Path of SMX_SAStorageEnclosureProcessor 2 (CIMObjectPath) 5 (Device Alert) 305 Time of the event or time of the indication if event time unknown HP SmartArray Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. Name of the computer system generating the indication CreationClassName of the computer system generating the indication HP_AlertIndication Fan Status changed to Degraded. 24 (Primary Storage Cooling) 94 (Fan failure) Fan Degraded Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication SMX_OperatingSystem.OSType Smart Array 146