HP BL685c HP Virtual Connect Manager Version 1.20 Release Notes and Compatibil - Page 16
Resolved issues
UPC - 883585312177
View all HP BL685c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Resolved issues The following issues that existed in Virtual Connect v1.16 have been resolved in Virtual Connect v1.20: • The Virtual Connect Manager now recovers from a dual-OA failover or the replacement of a single OA without requiring a reset of the Virtual Connect Manager. • Under certain fail-over conditions a loop could be caused for a very short window (up to about 120 mS). This time was sufficient for BPDUs to slip through and BPDUguard to run. • VC-FC Port operational and speed statuses reflected configuration settings rather than actual port status information. • VC-FC module no longer presents "Link to Management URL" in the OA graphical interface because web-based management is not available. • VC-FC module now supports SNMP and SMI-S management interfaces in read-only mode. • VC-FC corrected an issue with Non-Disruptive Code Load and Activation when all 16 server blades where logged in to the Fibre Channel SAN. • If non-Administrator credentials were entered for the Onboard Administrator during Virtual Connect Domain Import, the import failed without explanation. Resolved issues 16