HP BL860c HP Insight Foundation Suite for Integrity with Linux User's - Page 59

during reboot., stanza is inserted into the file. This new stanza is missing a line

Page 59 highlights

This is the result of the MPT Fusion driver rebuilding the initrd file and modifying elilo.conf when the it is installed. The following is a comparison of the elilo.conf file contents before and after the driver installation: Before After prompt timeout=20 default=linux relocatable image=vmlinuz-2.6.18-92.el5xen vmm=xen.gz-2.6.18-92.el5 label=linux initrd=initrd-2.6.18-92.el5xen.img read-only root=/dev/VolGroup00/LogVol00 append="-- rhgb quiet" prompt timeout=20 default=HP #Corresponds to kernel 2.6.18-92.el5xen # (previously, default=linux) relocatable image=vmlinuz-2.6.18-92.el5xen vmm=xen.gz-2.6.18-92.el5 label=linux initrd=initrd-2.6.18-92.el5xen.img read-only root=/dev/VolGroup00/LogVol00 append="-- rhgb quiet" # The following entry was added by Proliant HBA install script # in package mptlinux-4.00.13.01-3.rhel5 image=vmlinuz-2.6.18-92.el5xen label=HP #Corresponds to kernel 2.6.18-92.el5xen initrd=HP-initrd-2.6.18-92.el5xen.img read-only root=/dev/VolGroup00/LogVol00 append="-- rhgb quiet" The default variable is changed to HP that corresponds to the Xen kernel and a new image stanza is inserted into the file. This new stanza is missing a line, which causes the server hang during reboot. To avoid the system hangs during reboot, you must modify the file /etc/elilo.conf manually after the MPT Fusion driver is installed and before rebooting the server using the following steps: 1. Edit /etc/elilo.conf. 2. Add the following line immediately after the line, image=vmlinuz-2.6.18-92.el5xen in the label=HP stanza: vmm=xen.gz-2.6.18-92.el5 The file should now look like: prompt timeout=20 default=HP #Corresponds to kernel 2.6.18-92.el5xen # (previously, default=linux) relocatable image=vmlinuz-2.6.18-92.el5xen vmm=xen.gz-2.6.18-92.el5 label=linux initrd=initrd-2.6.18-92.el5xen.img read-only root=/dev/VolGroup00/LogVol00 append="-- rhgb quiet" # The following entry was added by Proliant HBA install script # in package mptlinux-4.00.13.01-3.rhel5 image=vmlinuz-2.6.18-92.el5xen vmm=xen.gz-2.6.18-92.el5 Installing the MPT Fusion HBA Driver on RHEL 5 and RHEL 5+ using a Xen Kernel Hangs the Server 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

This is the result of the MPT Fusion driver rebuilding the
initrd
file and modifying
elilo.conf
when the it is installed. The following is a comparison of the
elilo.conf
file contents before
and after the driver installation:
After
Before
prompt
timeout=20
default=HP
#Corresponds to kernel 2.6.18-92.el5xen
# (previously, default=linux)
relocatable
image=vmlinuz-2.6.18-92.el5xen
vmm=xen.gz-2.6.18-92.el5
label=linux
initrd=initrd-2.6.18-92.el5xen.img
read-only
root=/dev/VolGroup00/LogVol00
append="-- rhgb quiet"
# The following entry was added by Proliant
HBA install script
# in package mptlinux-4.00.13.01-3.rhel5
image=vmlinuz-2.6.18-92.el5xen
label=HP
#Corresponds to kernel 2.6.18-92.el5xen
initrd=HP-initrd-2.6.18-92.el5xen.img
read-only
root=/dev/VolGroup00/LogVol00
append="-- rhgb quiet"
prompt
timeout=20
default=linux
relocatable
image=vmlinuz-2.6.18-92.el5xen
vmm=xen.gz-2.6.18-92.el5
label=linux
initrd=initrd-2.6.18-92.el5xen.img
read-only
root=/dev/VolGroup00/LogVol00
append="-- rhgb quiet"
The
default
variable is changed to
HP
that corresponds to the Xen kernel and a new
image
stanza is inserted into the file. This new stanza is missing a line, which causes the server hang
during reboot.
To avoid the system hangs during reboot, you must modify the file
/etc/elilo.conf
manually
after the MPT Fusion driver is installed and
before
rebooting the server using the following steps:
1.
Edit
/etc/elilo.conf
.
2.
Add the following line immediately after the line,
image=vmlinuz-2.6.18-92.el5xen
in the
label=HP
stanza:
vmm=xen.gz-2.6.18-92.el5
The file should now look like:
prompt
timeout=20
default=HP
#Corresponds to kernel 2.6.18-92.el5xen
# (previously, default=linux)
relocatable
image=vmlinuz-2.6.18-92.el5xen
vmm=xen.gz-2.6.18-92.el5
label=linux
initrd=initrd-2.6.18-92.el5xen.img
read-only
root=/dev/VolGroup00/LogVol00
append="-- rhgb quiet"
# The following entry was added by Proliant HBA install script
# in package mptlinux-4.00.13.01-3.rhel5
image=vmlinuz-2.6.18-92.el5xen
vmm=xen.gz-2.6.18-92.el5
Installing the MPT Fusion HBA Driver on RHEL 5 and RHEL 5+ using a Xen Kernel Hangs the Server
59