HP BladeSystem bc2000 HP BladeSystem PC Blade Enclosure Integrated Administrat - Page 37
System Log, Toggle On/Toggle Off, Restart Integrated Administrator, Power Off Enclosure
View all HP BladeSystem bc2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
The Virtual Buttons screen (shown below) enables an enclosure administrator to modify the power state of the enclosure and Unit Identification LED from a remote location to facilitate troubleshooting by technicians in the data center. The Toggle On/Toggle Off button remotely changes the state of the enclosure Unit Identification LED. The illustration below shows the information presented in the Enclosure Power area of the Virtual Buttons screen: You can select the appropriate function with the following buttons: ● Restart Integrated Administrator - Restarts the Integrated Administrator and does not affect the blade PCs. Click Restart Integrated Administrator only at the direction of HP support personnel. Click Apply for these settings to take effect. ● Power Off Enclosure - Attempts a graceful shutdown of the system for 5 minutes, after which time this command powers down all components of the enclosure immediately. Whenever possible, HP recommends that you use the operating system shutdown procedures before powering down a blade PC or enclosure. After the enclosure is powered off, powering on can only occur by local access to the system. System Log The System Log screen (shown below) provides an enclosure administrator with a chronological list of events and fixes associated with the enclosure. ENWW Enclosure Tab 29