HP Brocade BladeSystem 4/12 Brocade EZSwitchSetup Administrator's Guide v6.2.0 - Page 27
Installing and running the EZSwitchSetup wizard, Discovery recovery, Symptom, Correction
View all HP Brocade BladeSystem 4/12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Installing and running the EZSwitchSetup wizard 2 TABLE 2 Symptom Discovery recovery The setup computer COM port is busy. The switch does not respond to commands during a serial connection. The switch does not power up. The switch's serial adapter does not work. Correction The port is being controlled by another communications program. Stop all other third-party communications programs. The port settings are in conflict with another device. Check your IRQ settings. On Windows systems: By default, COM1 and COM3 use IRQ4, while COM2 and COM4 use IRQ3. If another device is sharing the IRQ of the port, you need to change the IRQ of the conflicting device. Hardware conflicts can also occur with the I/O address of the COM port. The 8514a video chip or its clones (S3 chip set) on some video cards create a conflict with COM4 because they use the same address of 02E8. The serial cable may not be connected properly between the setup computer and the switch. Check the serial cable to ensure they are secured. Verify that the switch's power cable is securely plugged into a proper outlet and that the switch's power button is turned on. Verify that the cable is good by replacing the cable or trying it on another known working device. If the cable is good, then call your support provider for further instructions. EZSwitchSetup Administrator's Guide 15 53-1001193-02