A CFS de-register message is not sent when IVR is disabled.
View all HP Cisco MDS 9120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Caveats Send documentation comments to [email protected] Workaround: This issue is resolved. • CSCsr59106 Symptom: For two FCIP links on different modules but sharing a common DS3 pipe, the MDS switch could not saturate the DS3 pipe. In another setup with no latency and min/max-bw configured to 15mbps, the MDS FCIP shaper does not obey bandwidth rules and sends at a rate greater than 15mbps, which caused unnecessary drops in the network. This issue affects the MSM-18/4 module and the MDS 9222i switch. Workaround: This issue is resolved. • CSCsr62565 Symptom: With the Cimserver enabled, a zone is created and a device-alias member is added to the zone. Device-alias is in enhanced mode. While querying for ni/ei cisco_zonemembersettingdata, the Cimserver fails. Workaround: This issue is resolved. • CSCsr70045 Symptom: An FCIP link with an underlying Ethernet interface set to a large MTU (9000 bytes) flaps whenever data frames are sent. Control traffic (such as tape status check commands) are successful and do not cause flaps. This issue only occurs on an MSM-18/4 modules. Workaround: This issue is resolved. • CSCsr71466 Symptom: A CFS de-register message is not sent when IVR is disabled. Workaround: This issue is resolved. • CSCsr79043 Symptom: The entries for all configurations are not removed from pss when a VSAN is deleted. Workaround: This issue is resolved. • CSCsu03045 Symptom: A module gets stuck in the upgrading state if the LCM gets an error. Workaround: This issue is resolved. • CSCsu31909 Symptom: A failure in the internal software on the MSM-18/4 module causes an FCIP link in the PortChannel to drop. Workaround: This issue is resolved. • CSCsu44137 Symptom: A downgrade from NX-OS 4.1(1b) to SAN-OS 3.3(1c) is not supported on switches when FC-Redirect based applications like DMM and SME are configured in the fabric, if either of the following conditions are satisfied: - A target for which FC-Redirect is configured is connected locally, and there are Generation 1 modules with ISLs configured in the switch. - A host, for which FC-redirect is configured, is connected locally on a Generation 1 module. In such cases, remove the application configuration for such targets and hosts before proceeding with the downgrade. Workaround: This issue is resolved. OL-14116-10 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) 43