HP Disk System 2120 HP StorageWorks Disk System 2120 Users Guide (5697-5367, M - Page 24
HP StorageWorks Disk System 2120, Sample Hardware Event Notification, Event Class: I/O
View all HP Disk System 2120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
24 HP StorageWorks Disk System 2120 FIGURE 13 Sample Hardware Event Notification Notification Time: Wed Feb 3 11:27:15 1999 yourserver sent Event Monitor notification information: /storage/events/disks/default/10_4_4_0.0 is >=1. Its current value is CRITICAL(5) Event data from monitor: Event Time: Wed Feb 3 11:27:15 1999 Hostname: yourserver.rose.hp.com Event ID: 0x0036b8a313000000002 Event # : 100037 Severity : CRITICAL IP Address : 15.43.213.13 Monitor : disk_em Event Class: I/O Disk at hardware path 10/4/4/0.0 : Media failure Associated OS error log entry id(s) : 000000000000000000 Description of Error: The device was unsuccessful in reading data for the current I/ O request due to an error on the medium. The data could not be recovered. The request was likely processed in a way which could cause damage to or loss of data. Probable Cause / Recommended Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one. Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.