HP EVA4000/6000/8000 HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array r - Page 6
Supported Fibre Channel switches, Supported disks, Important notes and workarounds
![]() |
View all HP EVA4000/6000/8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Click Storage Networking under Storage, and then select HP StorageWorks SAN under HP StorageWorks SAN Solutions. Supported Fibre Channel switches For complete information on which Fibre Channel switches are supported on XCS 6.100 or later, see the HP StorageWorks SAN design reference guide, which can be downloaded from the following website: http://www.hp.com/support/manuals Click Storage Networking under Storage, and then select HP StorageWorks SAN under HP StorageWorks SAN Solutions. Supported disks For information about disk drive support, see HP StorageWorks Enterprise Virtual Array disk drive firmware support, available on the HP Manuals website: http://www.hp.com/support/manuals Under storage, click Disk Storage Systems, and then select the appropriate array model under EVA Disk Arrays. Important notes and workarounds This section identifies important notes and workarounds for the EVA4x00/6x00/8x00 hardware and XCS software. Upgrading to XCS 6.220 puts asynchronous DR groups in Temp Sync state Upgrading to XCS 6.220 from any version earlier than XCS 6.200 puts asynchronous DR groups in Temp Sync state. The XCS 6.xxx controller software has a Temp Sync state for DR groups that is used when a full copy is required. If the DR groups require a full copy when you initiate a controller software upgrade, the DR groups will move to the Temp Sync state upon completion of the upgrade and the full copy. You must reset the asynchronous mode for these DR groups, using HP Command View EVA or an equivalent command, to return to normal operations. HP recommends that you ensure the DR groups are not in a full copy state before upgrading to XCS 6.220. Changing the host port topology Before changing the topology settings of an array host port, physically disconnect the host port from its existing connection, change the topology setting, and then reconnect the host port. For example, to change from a fabric (switched) topology to a direct connect topology, do the following: 1. Disconnect the host port(s) from the Fibre Channel switch. 2. Using the operator control panel (OCP), change the controller host port mode from fabric to direct connect. 6
![](/manual_guide/products/hewlettpackard-eva4000-hp-storageworks-4x006x008x00-enterprise-virtual-array-release-notes-xcs-6220-56978035-2009-430f6db/6.png)