HP EVA8400 HP StorageWorks Enterprise Virtual Array Updating Product Software - Page 58
Initiating firmware code load, Storage system updating software - eva 8400 disk firmware
View all HP EVA8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
10. The upgrade process begins and the Initiating firmware code load page opens (see Figure 19 on page 58). This page is displayed while the upgrade file components are processed. Figure 19 Initiating firmware code load . CAUTION: If the upgrade is being performed on an EVA6400/8400 under heavy load, processing of the System Data Collector file component could time out and display one of the following error messages: If either error message appears, click OK. Another message appears indicating that the array is unresponsive; wait for communication between HP Command View EVA and the array to be reestablished. Once the array is available, the array appears as available in the navigation pane. Continue with step 10 to verify that the upgrade completed successfully. After Figure 19 appears, both controllers resynchronize and begin operating the new controller software. Once the re-synchronization is complete, the controllers begin processing host I/Os. Next, additional code within the storage system is updated, which can take up to 10 minutes to complete. This includes firmware on the I/O modules in the disk enclosures. During this interval, the Storage System Updating Firmware window opens (see Figure 20 on page 58). Figure 20 Storage system updating software 58 Upgrading the Enterprise Virtual Array