HP EliteDesk 705 Maintenance and Service Guide - Page 123

Control panel message, Description, Recommended action, 30C: Hard Disk 3-6: SMART Hard Drive

Page 123 highlights

Control panel message 302-Hard Disk 2: SMART Hard Drive Detects Imminent Failure 309 - 30C: Hard Disk 3-6: SMART Hard Drive Detects Imminent Failure 3F0-Boot Device Not Found 3F1-Hard Disk 1 Error 3F2-Hard Disk 2 Error 400-Serial Port A Address Conflict Detected 401-Serial Port B Address Conflict Detected 402-Serial Port C Address Conflict Detected Description Recommended action 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. Hard drive is about to fail. (Some hard drives 1. have a hard drive firmware patch that will fix an erroneous error message.) 2. 3. Determine if hard drive is giving correct error message. Run the Drive Protection System test under using F2 Diagnostics when booting the computer. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) Back up contents and replace hard drive. Hard drive is about to fail. (Some hard drives 1. have a hard drive firmware patch that will fix an erroneous error message.) 2. 3. Determine if hard drive is giving correct error message. Run the Drive Protection System test under using F2 Diagnostics when booting the computer. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) Back up contents and replace hard drive. Boot device not found. Insert boot device or load operating system. Hard disk 1 error. 1. Check and/or replace cables. 2. Clear CMOS. (See Password security and resetting CMOS on page 117.) 3. Replace the hard disk drive. Hard disk 2 error. 1. Check and/or replace cables. 2. Clear CMOS. (See Password security and resetting CMOS on page 117.) 3. Replace the hard disk drive. Both external and internal serial ports are assigned to the same resources. 1. Remove any serial port expansion cards. 2. Clear CMOS. (See Password security and resetting CMOS on page 117.) 3. Reconfigure card resources and/or run Computer Setup or Windows utilities. Both external and internal serial ports are assigned to the same resources. 1. Remove any serial port expansion cards. 2. Clear CMOS. (See Password security and resetting CMOS on page 117.) 3. Reconfigure card resources and/or run Computer Setup or Windows utilities. Both external and internal serial ports are assigned to the same resources. 1. Remove any serial port expansion cards. 2. Clear CMOS. (See Password security and resetting CMOS on page 117.) 3. Reconfigure card resources and/or run Computer Setup or Windows utilities. POST numeric codes and text messages 113

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

Control panel message
Description
Recommended action
2.
Apply hard drive
firmware
patch
if applicable. (Available at
support
.)
3.
Back up contents and replace hard drive.
302-Hard Disk 2: SMART Hard Drive Detects
Imminent Failure
Hard drive is about to fail. (Some hard drives
have a hard drive
firmware
patch that will
fix
an
erroneous error message.)
1.
Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2.
Apply hard drive
firmware
patch
if applicable. (Available at
support
.)
3.
Back up contents and replace hard drive.
309 – 30C: Hard Disk 3–6: SMART Hard Drive
Detects Imminent Failure
Hard drive is about to fail. (Some hard drives
have a hard drive
firmware
patch that will
fix
an
erroneous error message.)
1.
Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2.
Apply hard drive
firmware
patch
if applicable. (Available at
support
.)
3.
Back up contents and replace hard drive.
3F0–Boot Device Not Found
Boot device not found.
Insert boot device or load operating system.
3F1–Hard Disk 1 Error
Hard disk 1 error.
1.
Check and/or replace cables.
2.
Clear CMOS. (See
Password security and
resetting CMOS
on page
117
.)
3.
Replace the hard disk drive.
3F2–Hard Disk 2 Error
Hard disk 2 error.
1.
Check and/or replace cables.
2.
Clear CMOS. (See
Password security and
resetting CMOS
on page
117
.)
3.
Replace the hard disk drive.
400-Serial Port A Address
Conflict
Detected
Both external and internal serial ports are
assigned to the same resources.
1.
Remove any serial port expansion cards.
2.
Clear CMOS. (See
Password security and
resetting CMOS
on page
117
.)
3.
Reconfigure
card resources and/or run
Computer Setup or Windows utilities.
401-Serial Port B Address
Conflict
Detected
Both external and internal serial ports are
assigned to the same resources.
1.
Remove any serial port expansion cards.
2.
Clear CMOS. (See
Password security and
resetting CMOS
on page
117
.)
3.
Reconfigure
card resources and/or run
Computer Setup or Windows utilities.
402-Serial Port C Address
Conflict
Detected
Both external and internal serial ports are
assigned to the same resources.
1.
Remove any serial port expansion cards.
2.
Clear CMOS. (See
Password security and
resetting CMOS
on page
117
.)
3.
Reconfigure
card resources and/or run
Computer Setup or Windows utilities.
POST numeric codes and text messages