The LUN has encountered an Incorrect Initiator Connection. Examples include
View all HP High Availability FC Disk Array 30/FC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 267 highlights
Table 6-5 Sense Key, Additional Sense Code, and Additional Sense Code Qualifier Values (Not a Comprehensive List) (Continued) Sense key Description 0B/4E/00 The LUN has encountered an "Incorrect Initiator Connection." Examples include receiving two CDBs for the same I_T_L_Q nexus, or the mixing of tagged and untagged CDBs for a given I_T_L_Q nexus (with no outstanding Contingent Allegiance). Per the SCSI-2 specification, the SP will abort all outstanding CDBs for the I_T_L nexus. Troubleshooting Troubleshooting the Disk Array 6-19
Troubleshooting the Disk Array
6-19
Troubleshooting
0B/4E/00
The LUN has encountered an “Incorrect Initiator Connection.” Examples include
receiving two CDBs for the same I_T_L_Q nexus, or the mixing of tagged and
untagged CDBs for a given I_T_L_Q nexus (with no outstanding Contingent
Allegiance). Per the SCSI-2 specification, the SP will abort all outstanding CDBs
for the I_T_L nexus.
Table 6-5
Sense Key, Additional Sense Code, and Additional Sense Code Qualifier Values
(Not a Comprehensive List) (Continued)
Sense key