HP Indigo W7250 Dripping Prevention and ITM Heating Hood Service -- CA393-1010 - Page 40

Preliminary procedures, Dripping Correction Procedures, Press in Shutdown

Page 40 highlights

Preliminary procedures Follow these steps for preliminary procedures. 1. Verify press environment is within specifications (Refer to the relevant Site Preparation Guide): ● Required ambient temperature 20 to 25° C (68 to 77° F) ● Required ambient relative humidity 50 to 70 percent non-condensing ● Required fresh air flow +150 cfm 2. Check chiller set point: ● Temperature of water inlet to press between 1.5°C +/- 1° C (34.7° F +/- 33.8° F) ● Water circulation to press 65 L/min (17 gallons/min) Dripping Correction Procedures It explains the dripping correction procedures. Press in Shutdown Follow these steps to shutdown the press. 1. Shutdown the press software and computer. 2. Turn off the main power switch at the wall, and lock it in the OFF position. 3. Turn off the UPS and wait 1 minute for power to dissipate. 4. Verify that all press doors are closed properly. Check that the rubber seals are installed properly, and that they are not damaged. NOTE: The press should be sealed to prevent condensation, caused as a result of cold air penetration. 5. Check the cleaning station unit. For presses S/N 41000070 and below, verify that service note CA392-00941 (TN #1237) was implemented. WARNING! The press must be shut down when performing visual checks on the blowers. DO NOT put your hands inside any of the units while the press is still powered. Preliminary procedures 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Preliminary procedures
Follow these steps for preliminary procedures.
1.
Verify press environment is within specifications (Refer to the relevant Site Preparation Guide):
Required ambient temperature 20 to 25° C (68 to 77° F)
Required ambient relative humidity 50 to 70 percent non-condensing
Required fresh air flow +150 cfm
2.
Check chiller set point:
Temperature of water inlet to press between 1.5°C +/- 1° C (34.7° F +/- 33.8° F)
Water circulation to press 65 L/min (17 gallons/min)
Dripping Correction Procedures
It explains the dripping correction procedures.
Press in Shutdown
Follow these steps to shutdown the press.
1.
Shutdown the press software and computer.
2.
Turn off the main power switch at the wall, and lock it in the OFF position.
3.
Turn off the UPS and wait 1 minute for power to dissipate.
4.
Verify that all press doors are closed properly.
Check that the rubber seals are installed properly, and that they are not damaged.
NOTE:
The press should be sealed to prevent condensation, caused as a result of cold air
penetration.
5.
Check the cleaning station unit.
For presses S/N 41000070 and below, verify that service note CA392-00941 (TN #1237) was
implemented.
WARNING!
The press must be shut down when performing visual checks on the blowers.
DO NOT
put your hands inside any of the units while the press is still powered.
Preliminary procedures