HP Indigo W7250 Electrometer Board Test - Page 24
In the press UI, If nothing indicated on charge roller, then CR is
![]() |
View all HP Indigo W7250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
● If CCR indicated on charge roller, then CR is CCR. ● If nothing indicated on charge roller, then CR is Hydrin. 7. In the press UI: (Element activation -> Charge roller -> Electrometer), read the value in Electrometer field. Accepted results: 950V ± 100V. 22 Chapter 2 Procedures
![](/manual_guide/products/hewlettpackard-indigo-ws6000-electrometer-board-test-7735e0d/24.png)
●
If CCR indicated on charge roller, then CR is
CCR
.
●
If nothing indicated on charge roller, then CR is
Hydrin
.
7.
In the press UI: (
Element activation -> Charge roller -> Electrometer
), read the value in Electrometer field.
Accepted results: 950V ± 100V.
22
Chapter 2
Procedures