HP Integrity BL870c Windows Integrity Management Agents Reference - Page 78

System FW was unable to access the XBC semaphore. Probable Cause: System FW

Page 78 highlights

Event ID Event Severity Event Description 10481 Warning System Firmware was unable to access the configured set stored in the complex profile. Probable Cause: SFW was unable to access the configured set stored in the complex profile. Recommended Action: Collect IPMI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwUnAccesComplxProf - 10481 in HPIFPTRAP.MIB. 10482 Warning System Firmware detected an error during Fabric Init. Probable Cause: Error detected by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact your HP Support Representative for assistance. SNMP Trap: hpevtSysFwDetctErrFabInit - 10482 in HPIFPTRAP.MIB. 10483 Warning System Firmware detected a failure during Fabric Init. Probable Cause: Failure detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and contact your HP Support Representative for assistance. SNMP Trap: hpevtSysFwDetctFailFabInit - 10483 in HPIFPTRAP.MIB. 10487 Warning System Firmware detected an error during Fabric Optimize. Probable Cause: Error detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events and contact your HP Support Representative for assistance. SNMP Trap: hpevtSysFwDetctErrFabOptimz - 10487 in HPIFPTRAP.MIB. 10489 Warning Input power to the specified UPS has failed. SNMP Trap: hpevtInPwrUPSFail - 10489 in HPIFPTRAP.MIB. 10490 Warning Input power to the specified UPS has been restored. SNMP Trap: hpevtUpsRestored - 10490 in HPIFPTRAP.MIB. 10495 Error UPS power exhausted. The system is being powered down. SNMP Trap: hpevtUpsExhausted - 10495 in HPIFPTRAP.MIB. 10509 Warning During Machine Check handling, SAL failed to rendezvous all the processors. Probable Cause: System firmware cannot roundup the processors during the machine check handler. Recommended Action: Check for faulty processor, possibly the one(s) that failed to rendezvous. Contact your HP representative for support. SNMP Trap: hpevtSALFailRedzvsProcs - 10509 in HPIFPTRAP.MIB. 10510 Warning SAL failed to clear the CEC logs during Machine check handling. Probable Cause: System firmware failed to clear the CEC logs. Recommended Action: Check for multiple errors or bad CEC. Contact your HP representative for support. SNMP Trap: hpevtSALFailClrCECLog - 10510 in HPIFPTRAP.MIB. 10516 Warning System FW was unable to access the XBC semaphore. Probable Cause: System FW was unable to access the XBC semaphore. Recommended Action: Collect IPMI events, look for additional errors events, and contact HP support for assistance. SNMP Trap: hpevtSysFwUnAccesXBCSemphr - 10516 in HPIFPTRAP.MIB. 10518 Warning System Firmware detected an error while trying to release the XBC Global Semaphore. Probable Cause: Error detected by SFW while trying to release the XBC Global Semaphore. Recommended Action: Collect IPMI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwDetctErrRelXBCGlobSemphr - 10518 in HPIFPTRAP.MIB. 10519 Warning System Firmware detected an Error while checking the owner of the XBC Global Semaphore. Probable Cause: Error detected by SFW while checking the owner of the XBC Global Semaphore. Recommended Action: Collect IMPI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwDetctErrOwnXBCGlobSemphr - 10519 in HPIFPTRAP.MIB. 10520 Warning An error occurred while forming the XBC semaphore address Probable Cause: Couldn't determine the proper address of the XBC semaphore Recommended Action: Save IPMI event codes, contact HP Support Representative to analyze the fabric SNMP Trap: hpevtErrFormXbcSemphrAddr - 10520 in HPIFPTRAP.MIB. 10521 Warning Error reading the XBC Global Semaphore Probable Cause: Couldn't read the XBC semaphore Recommended Action: Look for additional IPMI event logs, contact your HP support representative to analyze the fabric SNMP Trap: hpevtErrRdXbcGlobSemphr - 10521 in HPIFPTRAP.MIB. 78 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
System Firmware was unable to access the configured set stored in the complex
profile. Probable Cause: SFW was unable to access the configured set stored in the
complex profile. Recommended Action: Collect IPMI events and contact your HP
Support Representative. SNMP Trap: hpevtSysFwUnAccesComplxProf - 10481 in
HPIFPTRAP.MIB.
Warning
10481
System Firmware detected an error during Fabric Init. Probable Cause: Error detected
by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact
your HP Support Representative for assistance. SNMP Trap:
hpevtSysFwDetctErrFabInit - 10482 in HPIFPTRAP.MIB.
Warning
10482
System Firmware detected a failure during Fabric Init. Probable Cause: Failure
detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and
contact your HP Support Representative for assistance. SNMP Trap:
hpevtSysFwDetctFailFabInit - 10483 in HPIFPTRAP.MIB.
Warning
10483
System Firmware detected an error during Fabric Optimize. Probable Cause: Error
detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events
and contact your HP Support Representative for assistance. SNMP Trap:
hpevtSysFwDetctErrFabOptimz - 10487 in HPIFPTRAP.MIB.
Warning
10487
Input power to the specified UPS has failed. SNMP Trap: hpevtInPwrUPSFail - 10489
in HPIFPTRAP.MIB.
Warning
10489
Input power to the specified UPS has been restored. SNMP Trap: hpevtUpsRestored
- 10490 in HPIFPTRAP.MIB.
Warning
10490
UPS power exhausted. The system is being powered down. SNMP Trap:
hpevtUpsExhausted - 10495 in HPIFPTRAP.MIB.
Error
10495
During Machine Check handling, SAL failed to rendezvous all the processors.
Probable Cause: System firmware cannot roundup the processors during the machine
check handler. Recommended Action: Check for faulty processor, possibly the one(s)
that failed to rendezvous. Contact your HP representative for support. SNMP Trap:
hpevtSALFailRedzvsProcs - 10509 in HPIFPTRAP.MIB.
Warning
10509
SAL failed to clear the CEC logs during Machine check handling. Probable Cause:
System firmware failed to clear the CEC logs. Recommended Action: Check for
multiple errors or bad CEC. Contact your HP representative for support. SNMP Trap:
hpevtSALFailClrCECLog - 10510 in HPIFPTRAP.MIB.
Warning
10510
System FW was unable to access the XBC semaphore. Probable Cause: System FW
was unable to access the XBC semaphore. Recommended Action: Collect IPMI events,
look for additional errors events, and contact HP support for assistance. SNMP Trap:
hpevtSysFwUnAccesXBCSemphr - 10516 in HPIFPTRAP.MIB.
Warning
10516
System Firmware detected an error while trying to release the XBC Global Semaphore.
Probable Cause: Error detected by SFW while trying to release the XBC Global
Semaphore. Recommended Action: Collect IPMI events and contact your HP Support
Representative. SNMP Trap: hpevtSysFwDetctErrRelXBCGlobSemphr - 10518 in
HPIFPTRAP.MIB.
Warning
10518
System Firmware detected an Error while checking the owner of the XBC Global
Semaphore. Probable Cause: Error detected by SFW while checking the owner of the
XBC Global Semaphore. Recommended Action: Collect IMPI events and contact your
HP Support Representative. SNMP Trap: hpevtSysFwDetctErrOwnXBCGlobSemphr
- 10519 in HPIFPTRAP.MIB.
Warning
10519
An error occurred while forming the XBC semaphore address Probable Cause:
Couldn't determine the proper address of the XBC semaphore Recommended Action:
Save IPMI event codes, contact HP Support Representative to analyze the fabric
SNMP Trap: hpevtErrFormXbcSemphrAddr - 10520 in HPIFPTRAP.MIB.
Warning
10520
Error reading the XBC Global Semaphore Probable Cause: Couldn't read the XBC
semaphore Recommended Action: Look for additional IPMI event logs, contact your
HP support representative to analyze the fabric SNMP Trap:
hpevtErrRdXbcGlobSemphr - 10521 in HPIFPTRAP.MIB.
Warning
10521