HP Integrity BL890c HP Insight Management WBEM Provider Events Reference Guide - Page 99

I/O discovery. Recommended Action: Replace drive. Update firmware on SAS

Page 99 highlights

14221 Error 14415 Warning 14431 Warning 14441 Error 14444 Error 14447 Warning 14450 Warning 14451 Warning 14452 Warning 14453 Warning The processor module that contains the Monarch Thread was deconfigured. Probable Cause: Unexpected Firmware or Hardware Error has been encountered. Recommended Action: AC power cycle the system. If the problem still occurs, contact Support for help. WBEM EventID: 9869. WBEM ProviderName: FPL_IndicationProvider. Invalid count reported for number of supported CPU p-states. Probable Cause: The processor is reporting invalid data about its power management information. Recommended Action: Verify that the System Firmware is at its supported revision, and if not, update firmware to the latest supported version. Replace the processor module. If problem persists contact support. WBEM EventID: 9884. WBEM ProviderName: FPL_IndicationProvider. Indicates an error has occurred while trying to reset SAS controllers. Probable Cause: An error has occurred while trying to reset the SAS controller after a GMCA or during I/O discovery. Recommended Action: Replace drive. Update firmware on SAS controller. Verify that the system firmware is at a supported revision. If problem persists, contact support. WBEM EventID: 9920. WBEM ProviderName: FPL_IndicationProvider. System firmware failed to publish ACPI tables. Probable Cause: The ACPI subsystem could not publish ACPI tables due to a System Firmware error. Recommended Action: Verify that the System Firmware is at its supported revision, and if not, update firmware to the latest supported version. If problem persists contact support. WBEM EventID: 9874. WBEM ProviderName: FPL_IndicationProvider. Indicates an inconstency in bus numbering has been discovered. Probable Cause: The busnumber returned by GetSystemSocketsInfo() does not match what is expected. Recommended Action: Ensure all systems in the enclosure are conjoined as required and functioning. Verify the SBL is installed and seated properly. If problem persists, contact support. WBEM EventID: 9928. WBEM ProviderName: FPL_IndicationProvider. software memory test failed. Probable Cause: Unexpected data accessed from the memory address during firmware memory test. Recommended Action: The first action will be check the system event logs for de-allocated DIMM(s). Next reseat the DIMM(s). If the problem persists, then replace the DIMM(s) with supported DIMM(s) - See Service Guide. If that does not solve the issue, replace CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9875. WBEM ProviderName: FPL_IndicationProvider. Scalable memory buffer (SMB) link initialization failed. Probable Cause: SMB (Scalable Memory Buffer) link initialization failed. Recommended Action: The first action will be to replace the CPU. If that does not solve the issue, reseat and/or replace with supported DIMM(s) associated with the SMB - See Service Guide. If problem still continues to exist, replace the system board. WBEM EventID: 9876. WBEM ProviderName: FPL_IndicationProvider. Scalable memory buffer (SMB) channel training failed. Probable Cause: Scalable memory buffer (SMB) channel training failed. Recommended Action: The first action will be to reset the CPU. If that does not solve the issue, replace CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9877. WBEM ProviderName: FPL_IndicationProvider. Memory build-in self test (MBIST) failed. Probable Cause: Memory Build-in self test failed. Recommended Action: The first action will be to check the SEL for the de-allocated DIMM(s). Next, reseat the failing DIMM(s). If that does not solve the issue, replace the DIMM(s) with supported DIMM(s) - See Service Guide. If problem still continues to exist, replace the system board. WBEM EventID: 9880. WBEM ProviderName: FPL_IndicationProvider. Memory build-in self test failed with timeout. Probable Cause: Memory built-in self test failed with timeout. Recommended Action: The first action will be to check the SEL for the de-allocated DIMM(s). Next, reseat the failing DIMM(s). If that does not solve the issue, replace the DIMM(s) with supported DIMM(s) - See Service Guide. If problem still continues to exist, replace the system board. WBEM EventID: 9881. WBEM ProviderName: FPL_IndicationProvider. Platform Events 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

The processor module that contains the Monarch Thread was deconfigured. Probable
Cause: Unexpected Firmware or Hardware Error has been encountered.
Recommended Action: AC power cycle the system. If the problem still occurs, contact
Support for help. WBEM EventID: 9869. WBEM ProviderName:
FPL_IndicationProvider.
Error
14221
Invalid count reported for number of supported CPU p-states. Probable Cause: The
processor is reporting invalid data about its power management information.
Recommended Action: Verify that the System Firmware is at its supported revision,
and if not, update firmware to the latest supported version. Replace the processor
module. If problem persists contact support. WBEM EventID: 9884. WBEM
ProviderName: FPL_IndicationProvider.
Warning
14415
Indicates an error has occurred while trying to reset SAS controllers. Probable Cause:
An error has occurred while trying to reset the SAS controller after a GMCA or during
I/O discovery. Recommended Action: Replace drive. Update firmware on SAS
controller. Verify that the system firmware is at a supported revision. If problem
persists, contact support. WBEM EventID: 9920. WBEM ProviderName:
FPL_IndicationProvider.
Warning
14431
System firmware failed to publish ACPI tables. Probable Cause: The ACPI subsystem
could not publish ACPI tables due to a System Firmware error. Recommended Action:
Verify that the System Firmware is at its supported revision, and if not, update
firmware to the latest supported version. If problem persists contact support. WBEM
EventID: 9874. WBEM ProviderName: FPL_IndicationProvider.
Error
14441
Indicates an inconstency in bus numbering has been discovered. Probable Cause:
The busnumber returned by GetSystemSocketsInfo() does not match what is expected.
Recommended Action: Ensure all systems in the enclosure are conjoined as required
and functioning. Verify the SBL is installed and seated properly. If problem persists,
contact support. WBEM EventID: 9928. WBEM ProviderName:
FPL_IndicationProvider.
Error
14444
software memory test failed. Probable Cause: Unexpected data accessed from the
memory address during firmware memory test. Recommended Action: The first
action will be check the system event logs for de-allocated DIMM(s). Next reseat the
DIMM(s). If the problem persists, then replace the DIMM(s) with supported DIMM(s)
- See Service Guide. If that does not solve the issue, replace CPU. If problem still
continues to exist, replace the system board. WBEM EventID: 9875. WBEM
ProviderName: FPL_IndicationProvider.
Warning
14447
Scalable memory buffer (SMB) link initialization failed. Probable Cause: SMB (Scalable
Memory Buffer) link initialization failed. Recommended Action: The first action will
be to replace the CPU. If that does not solve the issue, reseat and/or replace with
supported DIMM(s) associated with the SMB - See Service Guide. If problem still
continues to exist, replace the system board. WBEM EventID: 9876. WBEM
ProviderName: FPL_IndicationProvider.
Warning
14450
Scalable memory buffer (SMB) channel training failed. Probable Cause: Scalable
memory buffer (SMB) channel training failed. Recommended Action: The first action
will be to reset the CPU. If that does not solve the issue, replace CPU. If problem still
continues to exist, replace the system board. WBEM EventID: 9877. WBEM
ProviderName: FPL_IndicationProvider.
Warning
14451
Memory build-in self test (MBIST) failed. Probable Cause: Memory Build-in self test
failed. Recommended Action: The first action will be to check the SEL for the
de-allocated DIMM(s). Next, reseat the failing DIMM(s). If that does not solve the
issue, replace the DIMM(s) with supported DIMM(s) - See Service Guide. If problem
still continues to exist, replace the system board. WBEM EventID: 9880. WBEM
ProviderName: FPL_IndicationProvider.
Warning
14452
Memory build-in self test failed with timeout. Probable Cause: Memory built-in self
test failed with timeout. Recommended Action: The first action will be to check the
SEL for the de-allocated DIMM(s). Next, reseat the failing DIMM(s). If that does not
solve the issue, replace the DIMM(s) with supported DIMM(s) - See Service Guide.
If problem still continues to exist, replace the system board. WBEM EventID: 9881.
WBEM ProviderName: FPL_IndicationProvider.
Warning
14453
Platform Events