Parity error in Reg FIFO Internal parity error. Probable Cause: Parity error in Reg
View all HP Integrity rx7640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Event ID Event Severity 5407 Error 5408 Error 5411 Error 5416 Error 5417 Error 5418 Error 5419 Warning 5420 Error 5432 Error 5438 Warning 5440 Warning 5442 Error 5443 Error 5444 Error 5445 Error 5446 Error Event Description Crossbar slices are out of rev with each other. Probable Cause: Bad hardware configuration, different revisions of crossbars are installed. Recommended Action: Check crossbar revisions and ensure all installed crossbar revisions are the same. Replace the crossbar that is not in rev with the others. WBEM EventID: 363. WBEM ProviderName: FPL_IndicationProvider. Crossbar slices are configured poorly. Probable Cause: Fatal configuration. Reconfigure the hardware. WBEM EventID: 364. WBEM ProviderName: FPL_IndicationProvider. A CPU has taken over for the monarch CPU. Probable Cause: The previous monarch may be suspect. WBEM EventID: 365. WBEM ProviderName: FPL_IndicationProvider. Sram cannot be used on the cell. Probable Cause: SRAM cannot be located or used on the cell board. Replace the cell board. WBEM EventID: 366. WBEM ProviderName: FPL_IndicationProvider. The dillon hardware cannot be located. Probable Cause: ROM is corrupt. Replace the rom or reprogram flash. WBEM EventID: 367. WBEM ProviderName: FPL_IndicationProvider. A required piece of PDH bus hardware cannot be contacted. Probable Cause: Verify all connections of PDH bus components or replace the cell board. WBEM EventID: 368. WBEM ProviderName: FPL_IndicationProvider. Error: PCI Buses are configured for multiple speeds. Probable Cause: A PCI card is configured with mixed speeds. Recommended Action: Correct the configuration problem. WBEM EventID: 2420. WBEM ProviderName: FPL_IndicationProvider. The bus depth was exceeded during IO probing. Probable Cause: Too many PCI bridge cards are configured in single PCI segment mode. Recommended Action: Reconfigure PCI cards and remove some of the bridge devices. WBEM EventID: 2421. WBEM ProviderName: FPL_IndicationProvider. A Timeout occurred during RI initialization. The CSR is in the data field. The alert level will vary. Probable Cause: Hardware problem such as cable connect error or bad cables. Recommended Action: Correct the hardware problem and re-boot. WBEM EventID: 2422. WBEM ProviderName: FPL_IndicationProvider. SuperIO has been detected in slot. Probable Cause: SuperIO has been detected in the PCI slot. Recommended Action: No action required, information only. WBEM EventID: 2423. WBEM ProviderName: FPL_IndicationProvider. IO Link software error was corrected. Probable Cause: IO link error was detected and corrected. Recommended Action: No action required, information only. WBEM EventID: 372. WBEM ProviderName: FPL_IndicationProvider. Parity error in Reg FIFO Internal parity error. Probable Cause: Parity error in Reg FIFO. Recommended Action: Replace bad hardware. WBEM EventID: 374. WBEM ProviderName: FPL_IndicationProvider. TLB Fetch timeout. Probable Cause: SBA TLB fetch timeout error. Recommended Action: Replace faulty hardware. WBEM EventID: 375. WBEM ProviderName: FPL_IndicationProvider. Link presence goes away, FE. Probable Cause: Link presence lost on SBA interface. Recommended Action: Replace faulty hardware. WBEM EventID: 376. WBEM ProviderName: FPL_IndicationProvider. Elroy to REO parity error on command, rope will go fatal. Probable Cause: Bad hardware. Recommended Action: Replace I/O chassis. WBEM EventID: 377. WBEM ProviderName: FPL_IndicationProvider. Access to invalid TLB entry Requesting rope fatal. Probable Cause: An IO device is requesting access to an invalid TLB entry. Recommended Action: Driver problem debug driver. WBEM EventID: 378. WBEM ProviderName: FPL_IndicationProvider. 24 WBEM Provider Event Tables