HP LC2000r hp netserver lp 2000r netraid-2m config guide — for Mi - Page 3
Enclosure, Cables, Power distribution, Server, Network
View all HP LC2000r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
lp2000r2k2m Shared Storage Configuration Parameter Specification Configuration options Enclosure Cluster mode on Cache write policy to Write thru Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. Number of cabinets Model One or two Rack Storage/12 D5989C, containing two D6025C SCSI controller cards Status SCSI ID 5 (fixed) Disk SCSI IDs Cables 0-3, 8-15 (fixed) SCSI Power distribution Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Layout Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoftâ and HP Certified Server Configuration Parameter Server Specification I/O card slot PCI slot 1, NetRAID-2M shared storage controller Network interfaces Embedded NICs for both intra-cluster (heartbeat) and client LANs Boot device Embedded SCSI Intra-Cluster (Heartbeat) LAN Configuration Parameter Network Specification Connection NIC HP D5954A crossover cable, or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. Quantity One Model Embedded NIC - LAN A Driver Hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later) 10/21/02 3