HP LC2000r HP Netserver LXr 8000 NetRAID-3Si Config Guide for Windows NT4.0 C - Page 2

Storage

Page 2 highlights

Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage SP4 or later HP NetServer LXr 8000 400, 450, 500, or 550 MHz 2 - 4 ASPN1.86L.0003 or later (400/450 MHz with Rack Storage/12 Model D5989A) ASPN Release 10 (400/450 MHz with Rack Storage/12 Model D5989B) ASPN Release 10 (500/550 MHz) Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P3 - P4 Shared storage controller P1 - NetRAID-3Si local storage P5 - Client LAN P6 - Intra-cluster (Heartbeat) LAN All others - Any other plug-in cards. Local Physical drive location Disk drives Controller SCSI bus Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks Configuration options: SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8 or /12) Must be HP May use embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any controller listed on the HP Tested Products List. May not use NetRAID-1, NetRAID-3, or NetRAID-1Si. Any HP cables that meet SCSI specifications and any SCSI bus speed HP NetRAID-3Si Adapter D5955A 1 W.01.20 B.01.10 2.22 A.01.15 or later P3 - P4 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array Cluster mode on Cache write-policy to write-thru Set bus speed for Rack Storage/8 to Ultra Set any other options as you prefer 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

2
Service pack
SP4 or later
SPU
Model
HP NetServer LXr 8000
Clock speed
400, 450, 500, or 550 MHz
No. of CPUs
2 – 4
BIOS version
ASPN1.86L.0003 or later (400/450 MHz with Rack Storage/12 Model
D5989A)
ASPN Release 10 (400/450 MHz with Rack Storage/12 Model D5989B)
ASPN Release 10 (500/550 MHz)
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
I/O slots:
P3 – P4 Shared storage controller
P1 – NetRAID-3Si local storage
P5 – Client LAN
P6 – Intra-cluster (Heartbeat) LAN
All others – Any other plug-in cards.
Storage
Local
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8
or /12)
Disk drives
Must be HP
Controller
May use
embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any
controller listed on the HP Tested Products List.
May not use
NetRAID-1, NetRAID-3, or NetRAID-1Si.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.20
BIOS
B.01.10
Driver
2.22
NetRAID Assistant
A.01.15 or later
SPU I/O slot
P3 – P4
SCSI ID
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array
Configuration
options:
Cluster mode on
Cache write-policy to write-thru
Set bus speed for Rack Storage/8 to Ultra
Set any other options as you prefer