HP LD4200 HP LD4200 LCD Monitor User Guide - Page 61
Lamp fault Check (Command : d p), 30. Auto volume (Command : d u
UPC - 884420598480
View all HP LD4200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Transmission [d][n][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [n][][Set ID][][OK/NG][Data][x] * The data is 1 byte long in Hexadecimal. 29. Lamp fault Check (Command : d p) To check lamp fault. Transmission [d][p][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [p][][Set ID][][OK/NG][Data][x] Data 0 : Lamp Fault 1 : Lamp OK 30. Auto volume (Command : d u) Automatically adjust the volume level. Transmission [d][u][][Set ID][][Data][x] Data 0 : Off 1 : On Acknowledgement [u][][Set ID][][OK/NG][Data][x] ENWW Transmission / Receiving Protocol 53
Transmission
[d][n][][Set ID][][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[n][][Set ID][][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.
29. Lamp fault Check (Command : d p)
To check lamp fault.
Transmission
[d][p][][Set ID][][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[p][][Set ID][][OK/NG][Data][x]
Data 0 : Lamp Fault
1 : Lamp OK
30. Auto volume (Command : d u)
Automatically adjust the volume level.
Transmission
[d][u][][Set ID][][Data][x]
Data 0 : Off
1 : On
Acknowledgement
[u][][Set ID][][OK/NG][Data][x]
ENWW
Transmission / Receiving Protocol
53