HP LD4730 LD4730 and LD4730G LCD Ultraslim Bezel Digital Signage Displays Comm - Page 27
Set Off Timer., Transmission/Receiving Protocol
View all HP LD4730 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
(1FH): Monday to Friday (3FH): Monday to Saturday (60H): Saturday to Sunday [Data3] Every Week (write) 00H: Disable Every Week 01H: Enable Every Week [Data4] 00H to 17H, FFH (Hours) [Data5] 00H to 3BH, FFH (Minutes) When you read/delete the current on time list, all of [Data2][Data3][Data4][Data5] have to be FFH ex1: fd 01 F1 FF FF FF FF - when you read 1st index of On Time List ex2: fd 01 E1 FF FF FF FF - when you delete 1st index of On Time List ex3: fd 01 F1 3F 01 02 03 - when you write 1st index of On Time Data, "Monday to Saturday every week, 02:03" Acknowledgement [d][][Set ID][][OK][Data1][Data2][Data3][Data4][Data5][x] 37. Off Timer (On/Off Timer) Time (Command: f e) Set Off Timer. Transmission [f][e][][Set ID][][Data1][][Data2][][Data3][][Data4][][Data5][Cr] ENWW Transmission/Receiving Protocol 21