HP LH3000r HP LX Pro(e) NetRAID Config Guide for Windows NT4.0 Clusters - Page 2

Storage

Page 2 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Hot swap cages Local storage I/O slots: Storage Local Physical drive location Disk drives Cables Controller Shared Controller Model No. of controllers Firmware Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks Configuration options: HP NetServer LX Pro Model 1 or HP NetServer LXe Pro Model 1 166 or 200 MHz. 2 - 4 (at least 2 are required) 1.00.06.CDOL or later Any size 128 MB minimum. Must be HP. 3 May use for local storage; but not use for shared storage. Internal or external, using any controller. Must use HP disks. See Local Storage below. P6 - Shared storage controller P4 or P3 - NetRAID local storage P2 - Client LAN P1 - Intra-cluster (Heartbeat) LAN All others - Any other plug-in cards. SPU internal drive bays, or HP external drive cabinet (e.g., HP Storage System/6), or any combination. Must be HP Must be HP and < 3 m total length for external drive cabinet. SPU embedded controller or any controller (any number, manufacturer or driver) in any available I/O slot. Use P3 or P4 for NetRAID local storage. See SPU I/O slots above. HP NetRAID D4943A Use with HP Storage System/6 and HP Cluster Adapter only. 1 maximum S.01.00 2.03 A.01.09 P6 6, 7 0 and 1 only Do not use channel 2 for any purpose. 1, 5, 10 and 50 only 1 per RAID array 6 maximum per NetRAID adapter Cluster mode on (cache write-through, no hot spare) Ultra SCSI disabled Set any other options as you prefer 2

  • 1
  • 2
  • 3
  • 4

2
SPU
Model
HP NetServer LX Pro Model 1
or HP NetServer LXe Pro Model 1
Clock speed
166 or 200 MHz.
No. of CPUs
2 – 4 (at least 2 are required)
BIOS version
1.00.06.CDOL or later
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3
Hot swap cages
May use for local storage; but not use for shared storage.
Local storage
Internal or external, using any controller. Must use HP disks.
See
Local
Storage
below.
I/O slots:
P6 - Shared storage controller
P4 or P3 - NetRAID local storage
P2 - Client LAN
P1 - Intra-cluster (Heartbeat) LAN
All others - Any other plug-in cards.
Storage
Local
Physical drive location
SPU internal drive bays, or HP external drive cabinet (e.g., HP Storage
System/6), or any combination.
Disk drives
Must be HP
Cables
Must be HP and < 3 m total length for external drive cabinet.
Controller
SPU embedded controller or any controller (any number, manufacturer or
driver) in any available I/O slot.
Use P3 or P4 for NetRAID local
storage.
See
SPU I/O slots
above.
Shared
Controller
Model
HP NetRAID D4943A
Use with HP Storage System/6 and HP Cluster Adapter only.
No. of controllers
1 maximum
Firmware
S.01.00
Driver
2.03
NetRAID Assistant
A.01.09
SPU I/O slot
P6
SCSI ID
6, 7
Channels
0 and 1 only
Do not use channel 2 for any purpose.
RAID level
1, 5, 10 and 50 only
Logical disks
1 per RAID array
6 maximum per NetRAID adapter
Configuration
options:
Cluster mode on (cache write-through, no hot spare)
Ultra SCSI disabled
Set any other options as you prefer