HP LH4r hp lt 6000r and virtual array config guide — for Microsof - Page 3
Enclosure, Cables, Power distribution, Server, Network
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
LT6000R2K2M Shared Storage Configuration Parameter Enclosure Disk drives Number of cabinets Model Status SCSI ID Disk SCSI IDs Cables SCSI Power distribution Layout Specification Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. One or two per NetRAID-2M controller (up to four per cluster) Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 (fixed) Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoft® and HP Certified Server Configuration Parameter Server I/O controller Network interfaces Boot device Specification PCI slot 5, NetRAID-2M shared storage controller PCI slot 2, Client LAN Embedded NIC for intra-cluster (heartbeat) LAN Embedded DAC Intra-Cluster (Heartbeat) LAN Configuration Parameter Network Connection Specification HP D5954A crossover cable, or equivalent. NIC Quantity Model Driver The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. One Embedded NIC Hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later) 8/14/01 3