lt6000r2kxp Server Configuration Parameter I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification Added cards may be installed in any appropriate slot, considering the server default boot order provided below. IDE CD-ROM, FDD, embedded SCSI A, Embedded SCSI B, PCI slot 6, PCI slot 5, PCI slot 4, PCI slot 3, PCI slot 2, PCI slot 1 Embedded SCSI, or embedded DAC For embedded SCSI, sym_hi.sys, version 4.12, or later For embedded DAC, mraid35x.sys, version 2.66, or later (all drivers obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus speed Any Version L.20.00, or later Microsoft Windows® 2000 Advanced Server Latest service pack Redundant power distribution units (PDUs) are recommended. Shared Storage Configuration Parameter Controller Model Number of controllers Driver Enclosure Microcode RAID level LUN Emulations Disk drives Port host mode Port fabric mode Connections Fibre Channel Cables 50 meter 100 meter Specification HP Fibre Channel host bus adapter HP D8602B One Afcw2k.sys, version 3.0.4107.0 (driver obtained from Navigator CD-ROM, version M.04.00, or later) HP Surestore E Disk Array XP512 01-15-10-00/00 5 OPEN-3 Must be HP. Refer to support manuals. 08 Fabric Off/FC-AL On Direct Fibre Channel HP D6980A HP D6981A 12/11/01 2

  • 1
  • 2
  • 3
  • 4
  • 5

lt6000r2kxp
12/11/01
2
Server Configuration
Parameter
Specification
I/O slots
Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order
IDE CD-ROM, FDD, embedded SCSI A, Embedded SCSI B, PCI slot 6,
PCI slot 5, PCI slot 4, PCI slot 3, PCI slot 2, PCI slot 1
Local Storage
Controller
Embedded SCSI, or embedded DAC
Driver
For embedded SCSI, sym_hi.sys, version 4.12, or later
For embedded DAC, mraid35x.sys, version 2.66, or later
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location
Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs
Any
System software
Navigator CD-ROM
Version L.20.00, or later
Operating system
Service pack
Microsoft Windows
2000 Advanced Server
Latest service pack
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
Shared Storage Configuration
Parameter
Specification
Controller
HP Fibre Channel host bus adapter
Model
HP D8602B
Number of controllers
One
Driver
Afcw2k.sys, version 3.0.4107.0
(driver obtained from Navigator CD-ROM, version M.04.00, or later)
Enclosure
HP Surestore E Disk Array XP512
Microcode
01-15-10-00/00
RAID level
5
LUN Emulations
OPEN-3
Disk drives
Must be HP.
Refer to support manuals.
Port host mode
08
Port fabric mode
Fabric Off/FC-AL On
Connections
Direct Fibre Channel
Fibre Channel Cables
50 meter
HP D6980A
100 meter
HP D6981A