HP LH4r hp netserver lc 2000 netraid-3si config guide — for Micro - Page 3

Enclosure, Cables, Power Distribution, Server, Network

Page 3 highlights

lc20002k3Si Shared Storage Configuration Parameter Configuration options Specification Cluster mode on Cache write-policy to Write-thru Set any other option as desired Enclosure Disk drives Number of cabinets Model Status SCSI IDs Disk SCSI IDs Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. One, two, or three HP Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or HP Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0 - 3, 8 - 15 (fixed) Cables SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 4. Power Distribution Layout Redundant power distribution units (PDUs) are recommended. See powercabling diagram on page 6. Microsoft® and HP Certified Server Configuration Parameter Specification Server I/O controller Network interfaces Boot device PCI slot 1, NetRAID-1Si local storage controller PCI slot 5, NetRAID-3Si shared storage controller PCI slot 3, client LAN, model D5013B NIC NetRAID-1Si Intra-Cluster (Heartbeat) LAN Configuration Parameter Specification Network Connection HP D5954A crossover cable, or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. 01/26/02 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lc20002k3Si
01/26/02
3
Shared Storage Configuration
Parameter
Specification
Configuration options
Cluster mode on
Cache write-policy to Write-thru
Set any other option as desired
Enclosure
Disk drives
Any HP drive supported by storage enclosure.
Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets
One, two, or three
Model
HP Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
HP Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI IDs
5 (fixed)
Disk SCSI IDs
0 – 3, 8 – 15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page
4
.
Power Distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power-
cabling diagram
on page
6
.
Microsoft
®
and HP Certified Server Configuration
Parameter
Specification
Server
I/O controller
PCI slot 1, NetRAID-1Si local storage controller
PCI slot 5, NetRAID-3Si shared storage controller
Network interfaces
PCI slot 3, client LAN, model D5013B NIC
Boot device
NetRAID-1Si
Intra-Cluster (Heartbeat) LAN Configuration
Parameter
Specification
Network
Connection
HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication.
It
may not be used for client communication.