HP LH4r HP Netserver LC 3 NetRAID Config Guide for Windows NT4.0 Clusters - Page 2

Tested Products List and

Page 2 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots: LANs LAN connection NIC: Model Driver No. of NICs SPU I/O slot HP NetServer LC3 266 or 400 MHz. 1 - 2, but must be the same number of CPUs in each server 4.06.10 PQ Any size 64 MB minimum. Must be HP. Internal or external, using any controller. Must use HP disks. See Local Storage below. P5, P6 - Shared storage controller P4 - Intra-cluster (Heartbeat) LAN P1 - Client LAN All others - Any other plug-in cards. Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent only The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. Client LAN Any LAN HP D5013A (10/100TX PCI) (or HP J3171A) 2.24.00.0000 or later 1 P4 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver If the NIC used is the same as the Intra-cluster LAN, then the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum P1 2

  • 1
  • 2
  • 3
  • 4

2
SPU
Model
HP NetServer LC3
Clock speed
266 or 400 MHz.
No. of CPUs
1 – 2, but must be the same number of CPUs in each server
BIOS version
4.06.10 PQ
CPU cache
Any size
RAM
64 MB minimum.
Must be HP.
Local storage
Internal or external, using any controller. Must use HP disks.
See
Local Storage
below.
I/O slots:
P5, P6 - Shared storage controller
P4 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
All others - Any other plug-in cards.
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent only
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable.
It may not be used for client
communication.
NIC:
Model
HP D5013A
(10/100TX PCI)
(or HP J3171A)
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver
2.24.00.0000 or later
Any driver
If the NIC used is the same
as the Intra-cluster LAN,
then the Client LAN must
use the same driver as the
Intra-cluster LAN.
No. of NICs
1
1 minimum
SPU I/O slot
P4
P1