HP LH4r HP Netserver LC II Technical Reference Label - Page 1

HP LH4r - NetServer - 256 MB RAM Manual

Page 1 highlights

D4906-80201, Rev C OFF ON OFF ON OFF ON OFF ON System Board Terminator * CPU #1 0123 DIMMs Battery Voltage Regulator Module #1 System Switch Serial B Serial A CPU Frequency (by MHz) 233 266 300 333 CPU Speed Parallel I/O Mouse Keyboard Monitor Test (8 & 7) Password (6) Clear Password Config. Memory (5) Clear Config. (CMOS) Backplane To Control Panel SCSI A I C 7880 SCSI IDE CD-ROM Flexible Disk To System Board DIMM Installation 1 2 Remote Access To Management * Port PCI 6: LAN Adapter PCI 5: NetRAID 1 (Array Model) PCI 4 PCI 3 PCI 2 PCI 1 / ISA * Requires External Modem for Remote Access Boot Order 1. IDE CD-ROM 2. Floppy Drive 3. Embedded SCSI 4. PCI 6 5. PCI 5 6. PCI 4 7. PCI 3 8. PCI 2 9. PCI 1 CPU #2 Voltage Regulator Module #2 Video Controller 1MB VRAM Upgrade (D4219A) 1MB VRAM * Remove Terminator for CPU #2 Standard Model Control Panel System Board Backplane SCSI IDE CD-ROM Flexible Disk Cabling Key Available Connector Engaged Connector C42 68-pin SCSI Cable (5183-2412) D6 IDE CD-ROM Cable (5183-2411) FC Flexible Disk Cable (5183-2410) C52 68-pin SCSI Cable (5183-2484) I 2C I 2C Cable (5182-6730) C82 68-pin SCSI Cable (5183-3488) Built-in SCSI Terminator ** 68-pin to 50-pin Adapter (for tape backup only) (5183-2427) Flexible Disk CD-ROM Shelf 3 Shelf 4 Shelf 5 Shelf 6 Management Port Fan Cable Backplane Flexible Disk CD-ROM Power Supply C42 FC Shelf 1 D6 Shelf 2 Shelf 3 Shelf 4 Shelf 5 Shelf 6 ** Control Panel Flexible Disk CD-ROM Shelf 3 Hot-Swap Model System Board Default Switch Settings (1, 0, 3) OFF ON 1 2 3 4 5 6 SCSI ID 2 reserved for DAT Alternate Switch Settings (1, 2, 3) OFF ON 1 2 3 4 5 6 If Shelf 3 has SCSI ID set to 0 SCSI IDE CD-ROM Flexible Disk Flexible Disk Backplane FC Shelf 1 Management Port Fan Cable Backplane CD-ROM OUT sw IN End of Cable C52 C52 Shelf 2 Shelf 3 103 Rear View D6 C52 ** Array Model I 2C * C82 Power Supply * Shipped with the ARRAY Model only C52 NetRAID 1 NetServer LC II Service / Accessory Information Electronic Support Services • Internet Web Page http://www.hp.com/go/netserver • Internet FTP ftp://ftp.netserver.hp.com • CompuServe Library GO HPPC • HP NetServer BBS 1-208-344-1691 • HP Navigator CD Support Questions: • HP-Authorized Reseller • CompuServe Discussion Forum GO HPPC • US / Canada Phone Support 1-970-635-1000 • Europe Phone Support (+31-20) 581-3330 (Netherlands) HP has offices in over 100 countries. Check your local telephone directory. Optional HP 3 Year On-Site Support Pack • H5519A 3 Year, On-site, Same Day • H5514A 3 Year, On-site, 7 day / 24 hour • H5751A On-site Installation and Network Configuration Selected HP Accessories See your Hewlett-Packard Resellers for the following accessories: Mass Storage • D3583C 4.2GB Ultra SCSI Hot-Swap Disk Module (7200 RPM) • D4289A 9.1GB Ultra SCSI Hot-Swap Disk Module (7200 RPM) • D4903A 4.2GB 10K Ultra SCSI Hot-Swap Disk Module (10000 RPM) • D4383A 24X Max IDE CD-ROM • D4910A 4.2GB Ultra/Wide SCSI HDD (7200 RPM) • D4911A 9.1GB Ultra/Wide SCSI HDD (7200 RPM) Backup ∆ C5644A ∆ D1528H ∆ C1526H ∆ C1555B HP SureStore T4i 8GB ∆ Internal Tape Drive HP SureStore DAT8i ∆ Internal Tape Drive HP SureStore 5000i 4GB ∆ Internal Tape Drive HP SureStore 24i ∆ Internal Tape Drive ∆=Compressed Memory • D4295A • D4296A • D4297A 32MB DIMM 64MB DIMM 128MB DIMM Network Interface Card • D5013A HP NetServer LAN Adapter For other tested accessories, download the Order Assistant from the HP Web page. Audience Assumptions This Service Reference Label is for trained service personnel. Hewlett-Packard Company assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. Electrostatic Discharge To avoid catastrophic or hidden damage to components, wear a wrist strap and use a staticdissipative work surface connected to the chassis when handling components. Use an antistatic service kit, such as 3M® 8501/8502/8505 or equivalent. Even at low room temperatures, all covers and panels must be in place to provide controlled airflow for system reliability. This information is subject to change without notice and is provided without warranty. © 1997, Hewlett-Packard Company. All rights reserved. P/N: D4906-80201, Rev C

  • 1

Standard Model
1.
2.
3.
4.
5.
6.
7.
8.
9.
Boot Order
IDE CD-ROM
Floppy Drive
Embedded SCSI
PCI 6
PCI 5
PCI 4
PCI 3
PCI 2
PCI 1
System Board
1
2
CPU Frequency (by MHz)
D4906-80201, Rev C
See your Hewlett-Packard Resellers for the following accessories:
Selected HP Accessories
P/N: D4906-80201, Rev C
This information is subject to change without notice and is
provided without warranty.
For other tested accessories, download the Order Assistant
from the HP Web page.
Password (6)
Clear Password
Config. Memory (5)
Clear Config. (CMOS)
4.2GB Ultra SCSI Hot-Swap Disk Module (7200 RPM)
• D3583C
9.1GB Ultra SCSI Hot-Swap Disk Module (7200 RPM)
• D4289A
Remove Terminator
for CPU #2
DIMM Installation
NetServer LC II Service / Accessory
Information
Even at low room temperatures, all covers and panels must
be in place to provide controlled airflow for system reliability.
Audience Assumptions
This Service Reference Label is for trained service personnel.
Hewlett-Packard Company assumes you are qualified in the
servicing of computer equipment and trained in recognizing
hazards in products with hazardous energy levels.
Electrostatic Discharge
To avoid catastrophic or hidden
damage to components, wear a wrist strap and use a static-
dissipative work surface connected to the chassis when
handling components.
Use an antistatic service kit, such as
3M
8501/8502/8505 or equivalent.
®
© 1997, Hewlett-Packard Company.
All rights reserved.
• Internet Web Page
• Internet FTP
• CompuServe Library
GO HPPC
• HP NetServer BBS
1-208-344-1691
• HP Navigator CD
Electronic Support Services
HP has offices in over 100 countries.
Check your local
telephone directory.
Support Questions:
• HP-Authorized Reseller
• CompuServe Discussion Forum
GO HPPC
• US / Canada Phone Support
1-970-635-1000
• Europe Phone Suppor
t
(+31-20) 581-3330 (Netherlands)
=Compressed
Optional HP 3 Year On-Site Support Pack
3 Year, On-site, Same Day
• H5519A
On-site Installation and Network Configuration
• H5751A
3 Year, On-site, 7 day / 24 hour
• H5514A
Network Interface Card
HP NetServer LAN Adapter
• D5013A
Memory
32MB DIMM
• D4295A
64MB DIMM
• D4296A
128MB DIMM
• D4297A
HP SureStore 5000i 4GB
Internal Tape Drive
C1526H
HP SureStore 24i
Internal Tape Drive
C1555B
Backup
HP SureStore DAT8i
Internal Tape Drive
D1528H
HP SureStore T4i 8GB
Internal Tape Drive
C5644A
Mass Storage
24X Max IDE CD-ROM
• D4383A
4.2GB 10K Ultra SCSI Hot-Swap Disk Module
(10000 RPM)
• D4903A
9.1GB Ultra/Wide SCSI HDD (7200 RPM)
• D4911A
4.2GB Ultra/Wide SCSI HDD (7200 RPM)
• D4910A
Test (8 & 7)
CPU
Speed
Hot-Swap Model
Flexible Disk
Flexible Disk
CD-ROM
Shelf 2
Shelf 3
Shelf 4
Backplane
Shelf 1
Shelf 5
Shelf 6
SCSI
IDE CD-ROM
**
C42
D6
FC
Shipped with the
ARRAY Model only
*
NetRAID 1
Backplane
PCI 5: NetRAID 1
(Array Model)
PCI 4
PCI 3
PCI 2
PCI 1 / ISA
To Management
Port
*
To Control Panel
Flexible Disk
IDE CD-ROM
SCSI
*
Requires External Modem
for Remote Access
SCSI
A I C
7880
PCI 6: LAN Adapter
Remote
Access
To System Board
ON
OFF
266
ON
OFF
300
ON
OFF
233
ON
OFF
333
Flexible
Disk
Shelf 3
CD-ROM
Control
Panel
Backplane
Power Supply
Management
Port
Fan Cable
System Board
Backplane
Power Supply
Management
Port
Fan Cable
Shelf 4
Shelf 3
CD-ROM
Flexible
Disk
Shelf 5
Shelf 6
Control Panel
System Board
**
Flexible
Disk
Flexible Disk
CD-ROM
Shelf 2
Shelf 3
Backplane
Shelf 1
SCSI
IDE
CD-ROM
1
0
3
OUT
IN
Rear View
sw
End of
Cable C52
1
2
3
4
5
6
OFF
ON
Default Switch
Settings (1, 0, 3)
SCSI ID 2
reserved for DAT
1
2
3
4
5
6
OFF
ON
If Shelf 3 has
SCSI ID set to 0
Alternate Switch
Settings (1, 2, 3)
Cabling Key
Built-in SCSI Terminator
I
C
2
C82
I
C Cable (5182-6730)
2
I
C
2
68-pin to 50-pin Adapter (for
tape backup only) (5183-2427)
**
Available Connector
Engaged Connector
68-pin SCSI Cable (5183-2412)
C42
IDE CD-ROM Cable (5183-2411)
Flexible Disk Cable (5183-2410)
68-pin SCSI Cable (5183-2484)
68-pin SCSI Cable (5183-3488)
*
Monitor
0
1
2
3
Serial B
Serial A
Parallel
Mouse
Keyboard
Battery
System Switch
1MB VRAM
1MB VRAM Upgrade
(D4219A)
Video Controller
Voltage Regulator
Module #1
CPU #2
CPU #1
Voltage Regulator
Module #2
Terminator
I/O
DIMMs
*
D6
FC
C52
D6
FC
C52
*
Array Model
C82
C52
C52