HP LH4r HP Netserver LH 3 and LH 3r Quick Service Guide - Page 13

Specifications

Page 13 highlights

Specifications Operating Temperature Non-operating Temperature Operating Humidity Non-operating Humidity Operating Altitude Non-operating Altitude Minimum Clearance Front Sides Top Back Weight and Dimensions Height Width Depth Weight 5°to 35°C (41°to 95°F) -40° to +65° C (-40° to +149° F) 20% to 80% relative humidity, non-condensing 5% to 95% relative humidity, non-condensing -30 to 3,000 m (~10,000 ft) -30 to 12,000 m (~40,000 ft) 1 m (39 in) 2.5 cm (1.0 in) 2.5 cm (1.0 in) 15 cm (6.0 in) 494.8 mm (19.5 in) 350.5 mm (13.8 in) 724.2 mm (28.5 in) 35 - 50 kg (77 - 110 lb) LH 3 NOTE A fully-loaded NetServer can weigh up to 160 pounds (73 kg). Follow local safety regulations, and use one person for every 40 pounds (18 kg) of NetServer weight when lifting it. Weight and Dimensions LH 3r Height 354.7 mm (14 in) Width 482.6 mm (19 in) Depth 749.2 mm (29.5 in) Weight 35 - 50 kg (77 - 110 lb) NOTE A fully-loaded NetServer can weigh up to 160 pounds (73 kg). Follow local safety regulations, and use one person for every 40 pounds (18 kg) of NetServer weight when lifting it. Power supply input voltage Power supply output Sound pressure (LpA) Auto-Ranging Power Supply 100 to 127 VAC at 50/60 Hz 200 to 240 VAC at 50/60 Hz 90 to 132 VAC at 47 - 63 Hz 180 to 264 VAC at 47 - 63 Hz 550 W maximum (per module) 55 dB(A), bystander position 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

11
Specifications
Operating Temperature
5
°
to 35
°
C (41
°
to 95
°
F)
Non-operating
Temperature
-40° to +65° C (-40° to +149° F)
Operating Humidity
20% to 80% relative humidity, non-condensing
Non-operating Humidity
5% to 95% relative humidity, non-condensing
Operating Altitude
-30 to 3,000 m (~10,000 ft)
Non-operating Altitude
-30 to 12,000 m (~40,000 ft)
Minimum Clearance
Front
1 m (39 in)
Sides
2.5 cm (1.0 in)
Top
2.5 cm (1.0 in)
Back
15 cm (6.0 in)
Weight and Dimensions
LH 3
Height
494.8 mm (19.5 in)
Width
350.5 mm (13.8 in)
Depth
724.2 mm (28.5 in)
Weight
35 - 50 kg (77 - 110 lb)
NOTE
A fully-loaded NetServer can weigh up to 160 pounds (73 kg).
Follow local safety regulations, and use one person for every 40
pounds (18 kg) of NetServer weight when lifting it.
Weight and Dimensions LH 3r
Height
354.7 mm (14 in)
Width
482.6 mm (19 in)
Depth
749.2 mm (29.5 in)
Weight
35 - 50 kg (77 - 110 lb)
NOTE
A fully-loaded NetServer can weigh up to 160 pounds (73 kg).
Follow local safety regulations, and use one person for every 40
pounds (18 kg) of NetServer weight when lifting it.
Power supply
input voltage
Auto-Ranging Power Supply
100 to 127 VAC at 50/60 Hz
200 to 240 VAC at 50/60 Hz
90 to 132 VAC at 47 - 63 Hz
180 to 264 VAC at 47 - 63 Hz
Power supply output
550 W maximum (per module)
Sound pressure (LpA)
55 dB(A), bystander position