HP LH4r hp netserver lh 3000 netraid-2m config guide — for Micros - Page 3

Enclosure, Cables, Power distribution, Server, Network

Page 3 highlights

LH30002K2M Shared Storage Configuration Parameter Enclosure Disk drives Number of cabinets Model Status SCSI ID Disk SCSI IDs Cables SCSI Power distribution Layout Specification Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. One or two per NetRAID-2M controller (up to four per cluster) Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 (fixed) Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoft® and HP Certified Server Configuration Parameter Server I/O controller Network interfaces Boot device Specification PCI slot 2, NetRAID-2M shared storage controller PCI slot 6, Client LAN Embedded NIC for intra-cluster (heartbeat) LAN Embedded DAC Intra-Cluster (Heartbeat) LAN Configuration Parameter Network Connection Specification HP D5954A crossover cable, or equivalent. NIC Quantity Model Driver The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. One Embedded NIC Hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later) 8/13/01 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

LH30002K2M
8/13/01
3
Shared Storage Configuration
Parameter
Specification
Enclosure
Disk drives
Any HP drive supported by storage enclosure.
Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets
One or two per NetRAID-2M controller (up to four per cluster)
Model
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0–3, 8–15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page 5.
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 6.
Microsoft
°
and HP Certified Server Configuration
Parameter
Specification
Server
I/O controller
PCI slot 2, NetRAID-2M shared storage controller
Network interfaces
PCI slot 6, Client LAN
Embedded NIC for intra-cluster (heartbeat) LAN
Boot device
Embedded DAC
Intra-Cluster (Heartbeat) LAN Configuration
Parameter
Specification
Network
Connection
HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication.
It may
not be used for client communication.
NIC
Quantity
One
Model
Embedded NIC
Driver
Hptxnt5.sys, version
4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)