HP LH4r HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 2

Storage

Page 2 highlights

Intra-cluster (Heartbeat) LAN Power source System software: Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Embedded NIC with crossover cable. See Intra-cluster LAN below. Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.18.00 or later Microsoft Windows 2000 Advanced Server HP NetServer LH 3000 933 MHz. 2 4.06.24 PT or later Any size 256 MB minimum. Must be HP. 2 standard, 3 required for redundancy, 4 for redundant power cords See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8, PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P2 - Shared Storage - NetRAID-3Si P5 - Local storage - NetRAID-1Si P6 - Client LAN Booted from embedded DAC Storage Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID3Si. For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD or later. For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraid35x.sys 2.62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.00 or later
Operating System
Microsoft Windows 2000 Advanced Server
SPU
Model
HP NetServer LH 3000
Clock speed
933 MHz.
No. of CPUs
2
BIOS version
4.06.24 PT or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
2 standard, 3 required for redundancy, 4 for redundant power cords
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8,
PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration
P2 - Shared Storage - NetRAID-3Si
P5 - Local storage - NetRAID-1Si
P6 - Client LAN
Booted from embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-1Si, or NetRAID-
3Si.
Driver
For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD
or later.
For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62
(Navigator L.18.04.5 or later).
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed)
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraid35x.sys
2.62