HP LH4r HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 2

Storage

Page 2 highlights

Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration L.18.02 or later Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack SP6A or later HP NetServer LH3000 733, 800, 933 MHz 2 4.06.24 PT or later Any size 128 MB minimum. Must be HP. 2 standard, 3 required for redundancy, 4 for redundant power cords See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8, PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P2 - Shared Storage (NetRAID-3Si) P5 - Local Storage (NetRAID-1Si) P6 - Client LAN - D5013B Booted from embedded DAC Storage Local Controller Drivers Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si. For embedded SCSI, use sym_hi.sys version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID level Logical disks HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraidnt.sys 2.24 A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array, 8 maximum per NetRAID-3Si adapter 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Navigator version
L.18.02 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6A or later
SPU
Model
HP NetServer LH3000
Clock speed
733, 800, 933 MHz
No. of CPUs
2
BIOS version
4.06.24 PT or later
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
2 standard, 3 required for redundancy, 4 for redundant power cords
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8, PCI-7,
PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration
P2 - Shared Storage (NetRAID-3Si)
P5 – Local Storage (NetRAID-1Si)
P6 – Client LAN – D5013B
Booted from embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si.
Drivers
For embedded SCSI, use sym_hi.sys
version 4.12 or later.
For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraidnt.sys 2.24
NetRAID Assistant
A.01.15 or later
SCSI ID
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array, 8 maximum per NetRAID-3Si adapter