HP LH4r HP Netserver LH 4 FC Config Guide for Windows 2000 Advanced Server Cl - Page 2

Storage - netserver lh4

Page 2 highlights

System software: Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies I/O slots Default Boot Order M/S Certified Configuration Storage distribution units (PDU's) are strongly recommended. L.18.02 or later Microsoft Windows 2000 Advanced Server HP NetServer LH4 500, 550, 700 MHz 2 - 4 4.06.22 PS or later (500, 550 MHz) 4.06.32 PS or later (700 MHz) Any size 256 MB minimum. Must be HP. 3 required, 4 for redundancy Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-1, PCI-2, PCI-3, PCI-4, PCI-5, PCI-6, PCI-7, PCI-8 P1 -- Shared storage - FC HBA P3 - Client LAN - D5013B P4 - Intra-cluster (Heartbeat) LAN - D5013B P7 - Local storage (NetRAID-1Si) Booted from embedded SCSI. Local Controller Drivers Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si. For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD. For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed). Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level Required - D5991A HP Fibre Channel Host Bus Adapter - HP D8602A 1 Hhba5100.sys 2.06 0, 1, 3, 5 Cabinet RAID arrays HP NetServer Rack Storage/12FC- D5991A Not more than eight physical drives per logical array and not more than 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.02 or later
Operating System
Microsoft Windows 2000 Advanced Server
SPU
Model
HP NetServer LH4
Clock speed
500, 550, 700 MHz
No. of CPUs
2 – 4
BIOS version
4.06.22 PS or later (500, 550 MHz)
4.06.32 PS or later (700 MHz)
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3 required, 4 for redundancy
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind
the server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-1, PCI-2, PCI-3,
PCI-4, PCI-5, PCI-6, PCI-7, PCI-8
M/S Certified
Configuration
P1 -- Shared storage - FC HBA
P3 – Client LAN – D5013B
P4 – Intra-cluster (Heartbeat)
LAN – D5013B
P7 – Local storage (NetRAID-1Si)
Booted from embedded SCSI.
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-3Si or
NetRAID-1Si.
Drivers
For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server
CD.
For embedded DAC and NetRAID-xSi, use mraid35x.sys version
2.62
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed).
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
Required
– D5991A
Host Bus Adapter
Model
HP Fibre Channel Host Bus Adapter
- HP D8602A
No. of
HBAs
1
Driver
Hhba5100.sys
2.06
RAID level
0, 1, 3, 5
Cabinet
HP NetServer Rack Storage/12FC- D5991A
RAID arrays
Not more than eight physical drives per logical array and not more than