HP LH4r HP Netserver LH 4 FC Windows 2000 Config Guide for Windows 2000 Advan - Page 2

Storage - netserver lh4

Page 2 highlights

System software: Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: L.18.02 or later Microsoft Windows 2000 Advanced Server HP NetServer LH4 550, 700 MHz 2 - 4 4.06.22 PS or later (550 MHz) 4.06.32 PS or later (700 MHz) Any size 256 MB minimum. Must be HP. 3 required, 4 for redundancy See Local Storage below. P3 - Client LAN P4 - Intra-cluster (Heartbeat) LANs P7 - Free or Local storage (NetRAID-1Si) P8 -- Shared storage HBA Storage Local Controller Drivers Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids Boot from embedded SCSI. May use NetRAID-1Si in PCI slot P7 with BIOS disabled for additional local storage. May not use any other additional SCSI controllers. Use driver(s) supplied with Microsoft Windows 2000 Advanced Server. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed). Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver SPU I/O slot RAID level Cabinet RAID arrays No. of cabinets FC Array Cards Model (Required) HP Fibre Channel Host Bus Adapter - HP D8602A 1 Hhba5100.sys 2.06 P8 0, 1, 3, 5 Not more than eight physical drives per logical array and not more than eight LUNs are permitted in total. 1 HP Fibre Channel Array Controller - D5990A 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
System software:
Navigator version
L.18.02 or later
Operating System
Microsoft Windows 2000 Advanced Server
SPU
Model
HP NetServer LH4
Clock speed
550, 700 MHz
No. of CPUs
2 – 4
BIOS version
4.06.22 PS or later (550 MHz)
4.06.32 PS or later (700 MHz)
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3 required, 4 for redundancy
Local storage
See
Local Storage
below.
I/O slots:
P3 – Client LAN
P4 – Intra-cluster (Heartbeat)
LANs
P7 – Free or Local storage (NetRAID-1Si)
P8 -- Shared storage HBA
Storage
Local
Controller
Boot from embedded SCSI.
May use
NetRAID-1Si in PCI slot P7 with BIOS disabled for additional
local storage.
May not use
any other additional SCSI controllers.
Drivers
Use driver(s) supplied with Microsoft Windows 2000 Advanced Server.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed).
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
(Required)
Host Bus Adapter
Model
HP Fibre Channel Host Bus Adapter
- HP D8602A
No. of
HBAs
1
Driver
Hhba5100.sys
2.06
SPU I/O slot
P8
RAID level
0, 1, 3, 5
Cabinet
RAID arrays
Not more than eight physical drives per logical array and not more than
eight LUNs are permitted in total.
No. of cabinets
1
FC Array Cards
Model
HP Fibre Channel Array Controller - D5990A