HP LH4r HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 1
HP NetServer LH 4 with NetRAID-3Si (HP Rack Storage/12) Cluster Configuration Guide Windows 2000 Advanced Server Cluster Configuration Guide 22 February 2001 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LH 4 configurations with HP Rack - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 2
. See Intra-cluster LAN below. Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.18.00 or later Microsoft Windows 2000 Advanced Server HP NetServer LH 4 700 MHz - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 3
for each Rack Storage/12 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 4
supported driver NOTE If the NIC used is the same as the Intra-cluster LAN (D5013A/B), then the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 5
HP Microsoft Cluster Server with Rack Storage/12 5 - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 6
Power Cabling to Separate Power Sources 6 - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows 2000 Advanced - Page 7
Versions 22 February 2001 5 September 2000 Corrected boot order Initial release 7
HP NetServer LH 4
with
NetRAID-3Si (HP Rack Storage/12)
Cluster Configuration Guide
Windows 2000 Advanced Server
Cluster Configuration Guide
22 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LH 4 configurations with HP Rack Storage/12s and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers. This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH 4
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.