HP LH4r HP Netserver LH 4 Surestore E Installation Guide - Page 5

HP C2911A 0.9 meter 68-pin HD Male to 68-pin HD Male Cable

Page 5 highlights

No. of cabinets Disk modules: Power supply SureStore E Manager Cabling Terminator 1 - 6; Maximum 2 SureStore E 12Hs per SCSI bus. HP A3702A 4.2 GB Disk Module; HP A3703A 9.1 GB Disk Module; HP A3710A 18.2 GB Disk Module. 3 3.0 or later. HP C2981A 0.5 meter Ultra-flexible SCSI Cable; HP C2911A 0.9 meter 68-pin HD Male to 68-pin HD Male Cable; HP C2924A 2.5 meter 68-pin HD Male to 68-pin HD Male Cable; HP C2925A 10 meter 68-pin HD Male to 68-pin HD Male Cable. Maximum 25 meters per SCSI bus. HP C2905A Wide Differential SCSI Terminator. LANs LAN connection NIC: Model Driver No. of NICs SPU I\O slot Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent. The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. HP D5013A (10/100TX PCI) 3.00.06.004 or later 1 P2 Client LAN Any LAN Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver If the NIC used is the same as the Intra-cluster LAN, then the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum P1 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

3
No. of cabinets
1 – 6; Maximum 2 SureStore E 12Hs per SCSI bus.
Disk modules:
HP A3702A 4.2 GB Disk Module;
HP A3703A 9.1 GB Disk Module;
HP A3710A 18.2 GB Disk Module.
Power supply
3
SureStore E Manager
3.0 or later.
Cabling
HP C2981A 0.5 meter Ultra-flexible SCSI Cable;
HP C2911A 0.9 meter 68-pin HD Male to 68-pin HD Male Cable;
HP C2924A 2.5 meter 68-pin HD Male to 68-pin HD Male Cable;
HP C2925A 10 meter 68-pin HD Male to 68-pin HD Male Cable.
Maximum 25 meters per SCSI bus.
Terminator
HP C2905A Wide Differential SCSI Terminator.
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent.
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable.
It may not be used for client
communication.
NIC:
Model
HP D5013A
(10/100TX PCI)
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver
3.00.06.004 or later
Any driver
If the NIC used is the same as
the Intra-cluster LAN, then the
Client LAN must use the same
driver as the Intra-cluster LAN.
No. of NICs
1
1 minimum
SPU I\O slot
P2
P1