HP LH4r HP Netserver LH 4 with XP256 Cluster Config Guide for Windows NT4.0 C - Page 2
Storage - netserver lh4
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage HP NetServer LH4 400, 450, 500, or 550 MHz 2 - 4 4.06.23PS or later Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P1 - P3 Shared storage controller P1 - P3 NetRAID-3Si local storage P4 - Client LAN P5 - Intra-cluster (Heartbeat) LAN All others - Any other plug-in cards. Local Physical drive location Disk drives Controller SCSI bus Shared Host Bus Adapters Model Bus Protocol No. of HBAs/Server Firmware BIOS Driver SPU I/O slot SCSI ID Registry Changes SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP May use embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any controller listed on the HP Tested Products List. May not use NetRAID-1, NetRAID-3, or NetRAID-1Si. Any HP cables that meet SCSI specifications and any SCSI bus speed Fibre Channel HBA D8602A FC Public NL 1 NA NA 2.00 or later Available at http://www.semiconductor.agilent. com/io/hhba5101.html P3 - P4 NA I/O Timeout= 60 Seconds SCSI HBA A5252B or Adaptec AHA2944UW Ultra Wide or Fast Wide 1 N/A 2.11 (B.01.08) SP5 bundle version P3-P4 7 or 6 I/O Timeout=60 seconds Queue Tag Count=8 (MAXTAGS=8) 2