HP LH4r HP Netserver LH 6000 NetRAID-4M Config Guide for Windows NT4.0 Cluste - Page 2

Storage

Page 2 highlights

System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order Microsoft® and HP Certified Configuration Storage supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. M.02.00 or later Microsoft Windows NT® Server 4.0 Enterprise Edition SP6a HP Netserver LH 6000 900 MHz 2 - 6 4.06.38 PU or later Any size 128 MB minimum. Must be HP. 3 standard, 4 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8, PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P1 - Client LAN - D5013B P7- Shared Storage - NetRAID-4M Booted from Embedded DAC Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or NetRAID-2M. For embedded SCSI, use sym_hi.sys 4.12 or later. For Embedded DAC or NetRAID-xSi, use mraidnt.sys version 4.05 For NetRAID-1M/2M, use mraidnt.sys, version 4.05 or later. All are from Navigator L.20.00 or later. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any Shared Controller Model No. of controllers BIOS Firmware Driver NetRAID-4M FAST SCSI ID HP NetRAID-4M Adapter D9161A or D9351A 2 Disabled 4584 Hpn.sys version 2.4.0.4571 2.4-0 or later 6, 7 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
M.02.00 or later
Operating System
Service Pack
Microsoft Windows NT
Server 4.0 Enterprise Edition
SP6a
SPU
Model
HP Netserver LH 6000
Clock speed
900 MHz
No. of CPUs
2 - 6
BIOS version
4.06.38 PU or later
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3 standard, 4 required for redundancy
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8,
PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
Microsoft
and HP
Certified
Configuration
P1 – Client LAN – D5013B
P7– Shared Storage – NetRAID-4M
Booted from Embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-1Si, NetRAID-3Si,
NetRAID-1M or NetRAID-2M.
Driver
For embedded SCSI, use sym_hi.sys 4.12 or later.
For Embedded DAC or NetRAID-xSi, use mraidnt.sys version 4.05
For NetRAID-1M/2M, use mraidnt.sys, version 4.05 or later.
All are from Navigator L.20.00 or later.
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-4M Adapter D9161A or D9351A
No. of controllers
2
BIOS
Disabled
Firmware
4584
Driver
Hpn.sys version 2.4.0.4571
NetRAID-4M FAST
2.4-0 or later
SCSI ID
6, 7