HP LH4r HP Netserver LH 6000 with Model FC60 Config Guide for Windows NT4.0 C - Page 2

Storage

Page 2 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage HP NetServer LH 6000 550 Mhz 2-6 6.0.1 2 MB 2 GB. Must be HP. 3 See Local Storage below. Storage Local Controller Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids Shared HP SureStore E Disk Array FC60 Host Bus Adapter Model No. of HBAs Driver RAID level Array Controller Model RAID arrays Firmware Disk Enclosures May Use - Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot P1, otherwise any controller listed on the HP Tested Products List. May Not Use - NetRAID-1 or NetRAID-3 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed. Any (Required) HP D8602A 2 1.12 0, 1, 3, 5, or 0 & 1 A5635A HP SureStore E Disk Array FC60 Not more than 8 LUNs are permitted. 04.00.00.20 or later Up to 6 per array controller Disk Encolsure Model Number of disks A5636A HP SureStore E Disk System SC10 4,5,6,7,8,9 or 10 per enclosure 2

  • 1
  • 2
  • 3
  • 4

2
SPU
Model
HP NetServer LH 6000
Clock speed
550 Mhz
No. of CPUs
2-6
BIOS version
6.0.1
CPU cache
2 MB
RAM
2 GB.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
Storage
Local
Controller
May Use
- Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot P1,
otherwise any controller listed on the HP Tested Products List.
May Not Use
- NetRAID-1 or NetRAID-3
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP SureStore E Disk
Array FC60
(Required)
Host Bus Adapter
Model
HP D8602A
No. of HBAs
2
Driver
1.12
RAID level
0, 1, 3, 5, or 0 & 1
Array Controller
Model
A5635A HP SureStore E Disk Array FC60
RAID arrays
Firmware
Disk Enclosures
Not more than 8 LUNs are permitted.
04.00.00.20 or later
Up to 6 per array controller
Disk Encolsure
Model
A5636A HP SureStore E Disk System SC10
Number of disks
4,5,6,7,8,9 or 10 per enclosure