HP LH4r hp netserver lp 1000r netraid-2m config guide — for Micro - Page 2

Local Storage, System software, Power distribution, Controller

Page 2 highlights

lp1000rnt2m Server Configuration Parameter I/O slot Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification PCI slot 1 IDE CD-ROM, FDD, embedded SCSI, PCI slot 1 Embedded SCSI Sym_u3.sys, version 5.05.00, or later (driver obtained from Navigator CD-ROM L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus speed Any Version M.04.00, or later Microsoft Window NT® Server 4.0, Enterprise Edition SP5 or SP6a and Microsoft® hotfix Q316743. Please refer to the Microsoft® product support article at: http://support.microsoft.com/default.aspx?scid=KB;ENUS;q316743&ID=KB;EN-US;q316743 Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Shared Storage Configuration Parameter Controller Model Number of controllers BIOS Firmware Driver NetRAID Assistant SCSI ID Channels RAID levels Logical disks Configuration options Specification HP NetRAID-2M Controller, Model P3411A, or P3475A One Disabled Version H.01.08 (firmware obtained from Navigator CD-ROM, version M.04.00, or later) Mraidnt.sys, version 4.05 (driver obtained from Navigator CD-ROM, version L.20.00, or later) Version B.01.04, or later (software obtained from Navigator CD-ROM, version L.20.00, or later) 6, 7 0, 1 1, 5, 10, 50 One per RAID array Eight, maximum, per cluster Cluster mode on Cache write policy to Write thru 2/23/02 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lp1000rnt2m
2/23/02
2
Server Configuration
Parameter
Specification
I/O slot
PCI slot 1
Default boot order
IDE CD-ROM, FDD, embedded SCSI, PCI slot 1
Local Storage
Controller
Embedded SCSI
Driver
Sym_u3.sys, version 5.05.00, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)
Physical drive location
Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs
Any
System software
Navigator CD-ROM
Version M.04.00, or later
Operating system
Service pack
Microsoft Window NT
Server 4.0, Enterprise Edition
SP5 or
SP6a and Microsoft
hotfix Q316743.
Please refer to the Microsoft
product support article at:
US;q316743&ID=KB;EN-US;q316743
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 6.
Shared Storage Configuration
Parameter
Specification
Controller
Model
HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers
One
BIOS
Disabled
Firmware
Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.04.00, or later)
Driver
Mraidnt.sys, version 4.05
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
NetRAID Assistant
Version B.01.04, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
SCSI ID
6, 7
Channels
0, 1
RAID levels
1, 5, 10, 50
Logical disks
One per RAID array
Eight, maximum, per cluster
Configuration options
Cluster mode on
Cache write policy to Write thru