- HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 1
defines the supported HP NetServer LP2000r configurations using the HP Rack Storage/12FC and Microsoft® Cluster Server and one or two HP Rack Storage/12s. These configurations minimize single points of failure (SPOF, SPOFless1) and provide extended availability. The specific configuration certified - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 2
Ids SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level (Required) HP D8602B 1 AFCNT4.SYS - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 3
- 15 (fixed) Any HP drive supported by storage enclosure Optical (Server to Hub only): 50 HP D6976A 6-port fibre channel Or HP P4459A 8-port switch 1 for SPOF 2 for SPOFless with hubs LANs LAN connection Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or equivalent The intra-cluster LAN - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 4
Embedded Hptxnt.sys 4.02.35 or later No. of NICs 1 Any that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. Vendor supported driver. NOTE If the Client and Intracluster LANs are the same model, the Client LAN must use the same driver as the Intra-cluster - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 5
slots as follows: NetRAID-1M in P1 D8602B in P2 D5013B in P3 2. The bottom two shared storage devices are SCSI HP Rack Storage/12s and are optional to the cluster configuration. LEGEND Heavy (blue) lines are fibre channel Optical or Copper cables. See cabling in this guide for specifications. Dashed - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 6
Power Cabling to Separate Power Circuits (For SPOFless with 2 hubs, connect second hub to PDU that first hub is not attached to) 6 - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 7
as follows: NetRAID-1M in P1 HBA in slot P2 D5013B in P3 2. The bottom two shared storage devices are SCSI HP Rack Storage/12's and are optional to the cluster configuration. LEGEND Heavy (blue) lines are fibre channel optical or copper cables. See inside this guide for specifications. Solid red - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 8
follows NetRAID-1M in P1 HBA in P2 D5013B in P3 2. The bottom two shared storage devices are SCSI HP Rack Storage/12's and are optional to the cluster configuration. LEGEND Solid red lines are copper fibre channel. Dashed(green) lines are offset SCSI cables. See inside this guide for specifications - HP LH4r | HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 9
Versions 21 March 2001 Initial release 9
1
HP NetServer LP2000r
with
HP Rack Storage/12FC & HP Rack Storage/12
Cluster Configuration Guide
21 March 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LP2000r configurations using the HP Rack Storage/12FC
and Microsoft
Cluster Server and one or two HP Rack Storage/12s. These configurations minimize single
points of failure (SPOF, SPOFless
1
) and provide extended availability.
The specific configuration certified and
supported by both Hewlett-Packard and Microsoft
is defined, as are other guidelines to assist you in
configuring your clustered NetServers.
This guide is prescriptive; it describes the configurations supported by
HP.
Any deviance to these configurations can result in an inoperative cluster or an operating cluster with
degraded performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Racked Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LP2000r
Each node must be the same SPU, but may have different clock speeds,
main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12FC with two FCArray Cards, HP disks, and an HP
D8602B HBA in each server.
See
Shared Storage
below.
LANs:
Client LAN
Any that is HP and Microsoft
approved.
See
Client LAN
below.
For a SPOFless cluster, two D5013B NICs configured with AFT is
recommended (Add one NIC and pair with embedded).
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
1
For more information about configuring a SPOFless cluster, refer to the HP white paper,
High Availability
MSCS Cluster Solution