HP LH4r HP Netserver LP 2000r FC Config Guide for Windows NT4.0 Clusters - Page 2

Storage

Page 2 highlights

System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots Default Boot Order Microsoft® and HP Certified Configuration supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.20.00 or later Microsoft Windows NT® Server 4.0, Enterprise Edition SP6a or later HP NetServer LP2000r 1 GHz 2 4.06.16 or later Any size 256 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI P1 - Local storage (NetRAID-1M) P2 -Shared Storage HBA (D8602B) Booted from NetRAID-1M Storage Local Controller Driver May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M, or NetRAID-2M. For SPOFless, recommend NetRAID-xM with internal drives in RAID5, or another fault-tolerant RAID level. For embedded SCSI, use SYM_U3.SYS version 5.05 or later. For NetRAID-xSi, or For NetRAID-xM, use MRAIDNT.SYS version 4.05 or later. Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level (Required) HP D8602B 1 AFCNT4.SYS version 3.0.3245.1 0, 1, 3, 5, 10 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

2
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.20.00 or later
Operating System
Service Pack
Microsoft Windows NT
Server 4.0, Enterprise Edition
SP6a or later
SPU
Model
HP NetServer LP2000r
Clock speed
1 GHz
No. of CPUs
2
BIOS version
4.06.16 or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI
Microsoft
and HP
Certified
Configuration
P1 – Local storage (NetRAID-1M)
P2 –Shared Storage HBA (D8602B)
Booted from NetRAID-1M
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M,
or NetRAID-2M.
For SPOFless, recommend NetRAID-xM with internal drives in RAID-
5, or another fault-tolerant RAID level.
Driver
For embedded SCSI, use SYM_U3.SYS version 5.05 or later.
For NetRAID-xSi,
or
For NetRAID-xM, use MRAIDNT.SYS version 4.05 or later.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
(Required)
Host Bus Adapter
Model
HP D8602B
No. of HBAs
1
Driver
AFCNT4.SYS version 3.0.3245.1
RAID level
0, 1, 3, 5, 10