Power source System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order Microsoft® and HP Certified Configuration Storage Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.20.00 or later Microsoft Windows® 2000 Advanced Server SP1 HP NetServer LP2000r 1 GHz 2 4.06.19 or later Any size 256 MB minimum. Must be HP. 1 standard, 2 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI P1 - Shared Storage NetRAID-4M Embedded NICs - Intra-cluster and Client LANs Booted from embedded SCSI Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or NetRAID-2M. For embedded SCSI, use sym_hi.sys 4.12 or later. For NetRAID-xSi, use mraid35x.sys version 2.66. For NetRAID-1M/2M, use mraid2k.sys, version 5.20 or later. All are from Navigator L.20.00 or later. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any Shared Controller Model No. of controllers BIOS Firmware Driver NetRAID-4M FAST HP NetRAID-4M Adapter D9161A or D9351A 2 Disabled 4584 Hpn.sys version 2.4.0.4581 2.4-0 or later 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.20.00 or later
Operating System
Service Pack
Microsoft Windows
2000 Advanced Server
SP1
SPU
Model
HP NetServer LP2000r
Clock speed
1 GHz
No. of CPUs
2
BIOS version
4.06.19 or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
1 standard, 2 required for redundancy
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI
Microsoft
and HP
Certified
Configuration
P1 – Shared Storage NetRAID-4M
Embedded NICs – Intra-cluster and Client LANs
Booted from embedded SCSI
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or
NetRAID-2M.
Driver
For embedded SCSI, use sym_hi.sys 4.12 or later.
For NetRAID-xSi, use mraid35x.sys version 2.66
.
For NetRAID-1M/2M, use mraid2k.sys, version 5.20 or later.
All are from Navigator L.20.00 or later.
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-4M Adapter D9161A or D9351A
No. of controllers
2
BIOS
Disabled
Firmware
4584
Driver
Hpn.sys version 2.4.0.4581
NetRAID-4M FAST
2.4-0 or later