HP LH4r HP Netserver LP 2000r NetRAID-4M Config Guide for Windows NT4.0 Clust - Page 2
Storage
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order Microsoft® and HP Certified Configuration Storage supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.20.00 or later Microsoft Windows NT® Server 4.0 Enterprise Edition SP6a HP Netserver LP 2000r 1 GHz 2 4.06.19 or later Any size 128 MB minimum. Must be HP. 1 standard, 2 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI P1 - Shared Storage NetRAID-4M Embedded NICs - Intra-cluster and Client LANs Booted from embedded SCSI Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M or NetRAID-2M. For embedded SCSI, use sym_hi.sys 4.12 or later. For NetRAID-xSi, use mraidnt.sys version 4.05. For NetRAID-1M/2M, use mraidnt.sys, version 4.05 All are from Navigator L.20.00 or later. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any Shared Controller Model No. of controllers BIOS Firmware Driver NetRAID-4M FAST SCSI ID HP NetRAID-4M Adapter D9161A or D9351A 2 maximum Disabled 4584 Hpn.sys version 2.4.0.4571 2.4-0 or later 6, 7 2