HP LH4r HP Netserver LPr Rack Storage/12FC Config Guide for Windows NT4.0 Cl - Page 2

Storage

Page 2 highlights

Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack SP6a or later HP NetServer LPr 400, 450, 500, 550, 600, 650, 700 MHz. or higher 2 4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A) 4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B) 4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B) 4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B) Any size 128 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4 P1 - Local storage (NetRAID 1Si) P2 - Client LAN P3 - Shared Storage HBA P4 - Intra-cluster (Heartbeat) LAN Booted from embedded SCSI Local Controller Driver Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level Cabinet RAID arrays No. of cabinets FC Array Cards May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si. For embedded SCSI, use sym_hi.version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any (Required) HP D8602A 1 Hhba5100.sys 1.12 or later 0, 1, 3, 5, 10 Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6a or later
SPU
Model
HP NetServer LPr
Clock speed
400, 450, 500, 550, 600, 650, 700 MHz. or higher
No. of CPUs
2
BIOS version
4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A)
4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B)
4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B)
4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B)
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
M/S Certified
Configuration
P1 – Local storage (NetRAID 1Si)
P2 – Client LAN
P3 – Shared Storage HBA
P4 – Intra-cluster (Heartbeat) LAN
Booted from embedded SCSI
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver
For embedded SCSI, use sym_hi.version 4.12 or later.
For embedded DAC
and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
(Required)
Host Bus Adapter
Model
HP D8602A
No. of HBAs
1
Driver
Hhba5100.sys 1.12 or later
RAID level
0, 1, 3, 5, 10
Cabinet
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1
FC Array Cards