HP LH4r HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 1
HP NetServer LT 6000r with NetRAID-3Si (HP Rack Storage/12) Cluster Configuration Guide 30 January 2001 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LT 6000r configurations with HP Rack Storage/12 and Microsoft Cluster Server. These - HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 2
drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI Ids Channels HP NetRAID - HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 3
SCSI IDs Disk drives: Cables LANs LAN connection 1, 5, 10, 50 1 per RAID array 8 maximum per NetRAID-3Si adapter HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP - HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 4
supported driver. NOTE If the NIC used is the same type as the embedded NIC (D5013A/B), then the Client LAN NIC must use the same driver as the Intra-cluster NIC. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer - HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 5
HP Microsoft Cluster Server with Rack Storage/12 5 - HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 6
Bu tt on Button Power Cabling to Separate Power Circuits 6 - HP LH4r | HP Netserver LT 6000 NetRAID-3Si Config Guide for Windows NT4.0 Clust - Page 7
Versions 30 January 2001 3 November 2000 16 October 2000 6 September 2000 26 May 2000 Added D6025C support Corrected errors re:Windows 2000 drivers and references. Updated 3Si firmware from W.01.20. Added Ultra3 disk drives. Revised intro and boot specs. Initial release. 7
1
HP NetServer LT 6000r
with
NetRAID-3Si (HP Rack Storage/12)
Cluster Configuration Guide
30 January 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LT 6000r configurations with HP Rack Storage/12 and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Racked Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LT 6000r
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks. See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power